Enhanced Eye Velocity With Backup Saccades in vHIT Tests of a Menière Disease Patient: A Case Report

Author:

Soriano-Reixach Maria Montserrat,Rey-Martinez Jorge,Altuna Xabier,Curthoys Ian

Abstract

Reduced eye velocity and overt or covert compensatory saccades during horizontal head impulse testing are the signs of reduced vestibular function. However, here we report the unusual case of a patient who had enhanced eye velocity during horizontal head impulses followed by a corrective saccade. We term this saccade a “backup saccade” because it acts to compensate for the gaze position error caused by the enhanced velocity (and enhanced VOR gain) and acts to return gaze directly to the fixation target as shown by eye position records. We distinguish backup saccades from overt or covert compensatory saccades or the anticompensatory quick eye movement (ACQEM) of Heuberger et al. (1) ACQEMs are anticompensatory in that they are in the same direction as head velocity and so, act to take gaze off the target and thus require later compensatory (overt) saccades to return gaze to the target. Neither of these responses were found in this patient. The patient here was diagnosed with unilateral definite Meniere's disease (MD) on the right and had enhanced VOR (gain of 1.17) for rightward head impulses followed by backup saccades. For leftwards head impulses eye velocity and VOR gain were in the normal range (VOR gain of 0.89). As further confirmation, testing with 1.84 Hz horizontal sinusoidal head movements in the visual-vestibular (VVOR) paradigm also showed these backup saccades for rightwards head turns but normal slow phase eye velocity responses without backup saccades for leftwards had turns. This evidence shows that backup saccades can be observed in some MD patients who show enhanced eye velocity responses during vHIT and that these backup saccades act to correct for gaze position error caused by the enhanced eye velocity during the head impulse and so have a compensatory effect on gaze stabilization.

Publisher

Frontiers Media SA

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3