A study on out-of-field leakage of an accelerator-based neutron beam for boron neutron capture therapy

Author:

You Zhen-Fan,Huang Chun-Kai,Liu Yen-Wan Hsueh

Abstract

More and more accelerator-based boron neutron capture therapy (AB-BNCT) facilities are under the construction or commissioning stage, and the neutron beam characteristic measurements at each facility will start soon. In addition to the in-field neutron beam properties, the leakage of neutron beam is also important, which is related to the side effects of the patient. In the Virtual Technical Meeting on Advances in Boron Neutron Capture Therapy held by International Atomic Energy Agency (IAEA) in July 2020, the issue of the out-of-field leakage in BNCT was addressed. Heron Neutron Medical Corporation has been working on the beam design for China Medical University Hsinchu Hospital AB-BNCT research center. To evaluate the out-of-field leakage, both beam profile analysis and whole-body dose calculation are performed. An Oak Ridge National Laboratory (ORNL) Medical Internal Radiation Dose (MIRD) mathematical phantom is used to calculate the whole-body dose. For the estimated irradiation time which is set to be the time required for 80% of tumor dose to reach 20 Gy-w, the relative biological effectiveness weighted dose of abdomen region is less than 40 mGy-w and the whole-body dose is 104 mSv. The beam profile calculational result shows that the neutron ambient dose equivalent at 15 cm from the field edge is 11 mSv/Gy-w and drops to 5 mSv/Gy-w at 26 cm from the field edge. The gamma ray ambient dose equivalent is less than 1 mSv/Gy-w starting from 10 cm from the field edge. Although the neutron out-of-field leakage of the beam design is higher than that of the initially proposed guideline by IAEA in 2020, the whole-body dose, however, is reasonably low. Both the whole-body dose evaluation and the beam profile analysis are useful in the beam design consideration. The whole-body dose calculation together with the beam profile analysis can also be helpful in reaching an acceptable recommendation for the out-of-field leakage for BNCT neutron beam, a job wished to be accomplished in the near future as proposed in the 2023 IAEA’s report on Advances in Boron Neutron Capture Therapy.

Publisher

Frontiers Media SA

Reference12 articles.

1. Monte carlo based dosimetry and treatment planning for boron neutron capture therapy of brain tumors;Zamenhof;Basic Life Sciences,1990

2. Out-of-field Leakage in Boron Neutron Capture Therapy;Koivunoro,2020

3. Input files with ORNL—Mathematical phantoms of the human body for MCNP-4B;Krstić;Comput Phys Commun,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3