Dosimetric Comparison of Intraoperative Radiotherapy and SRS for Liver Metastases

Author:

Scafa Davide,Muedder Thomas,Holz Jasmin A.,Koch David,Nour Younéss,Garbe Stephan,Gonzalez-Carmona Maria A.,Feldmann Georg,Vilz Tim O.,Köksal Mümtaz,Giordano Frank A.,Schmeel Leonard Christopher,Sarria Gustavo R.

Abstract

Purpose/ObjectivesTo perform a dosimetric comparison between kilovoltage intraoperative radiotherapy (IORT) and stereotactic radiosurgery (SRS) simulating both deep-inspiration breath-hold (DIBH) and free-breathing (FB) modalities for patients with liver metastases.Methods/MaterialsDiagnostic computed tomographies (CT) of patients carrying one or two lesions <4 cm and who underwent surgery were retrospectively screened and randomly selected for the study. For DIBH-SRS, a gross target volume (GTV) plus planning target volume (PTV) were delineated. For FB-SRS, a GTV plus an internal target volume (ITV) and PTV were defined. Accounting for the maximal GTV diameters, a modified GTV (GTV-IORT) was expanded circumferentially to simulate a resection cavity. The best suitable round-applicator size was thereafter selected. All treatment plans were calculated homogeneously to deliver 40 Gy. Doses delivered to organs at risk (OAR) and target volumes were compared for IORT vs. both SRS modalities.ResultsEight patients encompassing 10 lesions were included in the study. The mean liver volume was 2,050.97 cm3 (SD, 650.82), and the mean GTV volume was 12.23 cm3 (SD, 12.62). As for target structures, GTV-IORT [19.44 cm3 (SD, 17.26)] were significantly smaller than both PTV DIBH-SRS [30.74 cm3 (SD, 24.64), p = 0.002] and PTV FB-SRS [75.82 cm3 (SD, 45.65), p = 0.002]. The median applicator size was 3 cm (1.5–4.5), and the mean IORT simulated delivery time was 45.45 min (SD, 19.88). All constraints were met in all modalities. Liver V9.1 showed significantly smaller volumes with IORT [63.39 cm3 (SD, 35.67)] when compared to DIBH-SRS [150.12 cm3 (SD, 81.43), p = 0.002] or FB-SRS [306.13 cm3 (SD, 128.75), p = 0.002]. No other statistical or dosimetrically relevant difference was observed for stomach, spinal cord, or biliary tract. Mean IORT D90 was 85.3% (SD, 6.05), whereas D95 for DIBH-SRS and FB-SRS were 99.03% (SD, 1.71; p = 0.042) and 98.04% (SD, 3.46; p = 0.036), respectively.ConclusionKilovoltage IORT bears the potential as novel add-on treatment for resectable liver metastases, significantly reducing healthy liver exposure to radiation in comparison to SRS. Prospective clinical evidence is required to confirm this hypothesis.

Publisher

Frontiers Media SA

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3