Author:
Xu Yu,Zhang Wenjing,Xia Tingting,Liu Yuliang,Bi Zhoukui,Guo Liang,Xie Weijia,Xiang Ying,Xu Zhi,Yu Zubin,Li Yafei,Bai Li
Abstract
IntroductionThe diagnostic value of 7 tumor-associated autoantibodies (AABs) including p53, PGP9.5, SOX2, GAGE7, GBU4-5, MEGEA1, and CAGE for the detection of lung cancer has shown inconsistency in several studies. This study aimed to confirm the diagnostic value of 7AABs and to explore whether the diagnostic value would be improved by combining them with 7 traditional tumor-associated antigens (CEA, NSE, CA125, SCC, CA15-3, pro-GRP, and CYFRA21-1) in clinical settings.MethodsThe plasma levels of 7-AABs were detected by enzyme-linked immunosorbent assay (ELISA) in 533 lung cancer cases and 454 controls. The 7 tumor antigens (7-TAs) were measured by Electrochemiluminescence immunoassay with Cobas 6000 (Roche, Basel, Switzerland).ResultsThe positive rate of 7-AABs in the lung cancer group (64.00%) was significantly higher than that of healthy controls (47.90%). The 7-AABs panel was able to discriminate lung cancer from controls with a specificity of 51.50%. After combining the 7-AABs with 7-TAs, the sensitivity showed a significantly enhancement compared with 7AABs panel alone (92.09% vs 63.21%). In patients with resectable lung cancer, the combination of 7-AABs and 7-TAs improved the sensitivity from 63.52% to 97.42%DiscussionIn conclusion, our study found that the diagnostic value of 7-AABs was enhanced when combined with 7-TAs. This combined panel could be used as promising biomarker to detect resectable lung cancer in clinical settings.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献