Practice of standardization of CLSI M45 A3 antimicrobial susceptibility testing of Infrequently Isolated or Fastidious Bacteria strains isolated from blood specimens in Guangdong Province 2017–2021

Author:

He Nanhao,Yang Xu,Haque Anwarul,Chen Jiakang,Guo Yingyi,Li Jiahui,Yao Likang,Zhuo Chuyue,Wang Jiong,Wang Yijing,Li Mingxin,Lin Yexin,Xiao Shunian,Zhuo Chao

Abstract

The concentration of antimicrobial agents in environments like water and food has increased rapidly, which led to a rapid increase in antimicrobial resistance levels in the environment. Monitoring of bacterial resistance levels is considered as a necessary means to control the bacterial resistance. Reference standards are critical for antimicrobial susceptibility testing. CLSI M45 A3 standard defines pathogenic microorganisms that cause infections less frequently than those covered by CLSI M02, M07, and M100 as Infrequently Isolated or Fastidious Bacteria and specifies antimicrobial susceptibility testing methods. Our study investigated the epidemiology and antimicrobial susceptibility testing data of Infrequently Isolated or Fastidious Bacteria strains isolated from blood specimens in 70 hospitals in Guangdong Province between 2017 and 2021. We defined testing methods other than those specified in CLSI M45 A3 as “Non-Standardized.” The proportion of standardized antimicrobial susceptibility testing for penicillin increased significantly (Corynebacterium spp. 17.4% vs. 50.0% p < 0.05; Micrococcus spp. 50.0% vs. 77.8% p < 0.05; Abiotrophia spp. and Granulicatella spp. 21.4% vs. 90.9% p < 0.001), while for cefotaxime (Corynebacterium spp. 0.0% vs. 45.2% p < 0.05; Abiotrophia spp. and Granulicatella spp. 0.0% vs. 14.3% p = 0.515) and vancomycin increased finitely. Non-standardized methods were used for all other antimicrobials. Due to limitations in the economic and medical environment, some clinical laboratories are unable to fully comply with CLSI M45 A3 standard. We recommend that CLSI should add breakpoints for disk diffusion method to improve the standardization of antimicrobial susceptibility testing.

Publisher

Frontiers Media SA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3