Does endovascular duration impact clinical outcomes in aortic arch repair? The RELAY™ branched international stance

Author:

Tan Sven Z. C. P.,Surkhi Abedalaziz O.,Jubouri Matti,Bailey Damian M.,Williams Ian M.,Bashir Mohamad

Abstract

BackgroundThe high mortality and morbidity rates in surgical aortic arch repair are a barrier to therapy for a considerable proportion of patients with aortic arch aneurysm or dissection. There is hence a demand for the development and adoption of a minimally invasive alternative to aortic arch repair, such as thoracic endovascular aortic repair (TEVAR). Procedural duration is a key factor in the pathogenesis of complications in surgical aortic arch repair. Herein, we evaluate whether endovascular duration impacts neurological outcomes, target vessel patency, and reintervention rates in aortic arch TEVAR with RELAY™ Branched (Terumo Aortic, Inchinnan, UK), which is specifically developed for on-label use within the aortic arch.MethodsProspective data was collected between January 2019 and January 2022 on the clinical outcomes of TEVAR for aortic arch dissection and aneurysm with RELAY™ single-, double-, and triple branched endoprostheses from centers across Europe. They were then retrospectively analyzed with descriptive and distributive analysis. Follow-up data on the incidence of disabling stroke (DS), target vessel patency, and reintervention from 30 days and 6-, 12-, and 24 months postoperative was included in the analysis.Results147 (99.3%) of all 148 cases were successful. Over the 24 month follow-up period, in total 6 (4.1%) patients suffered DS, 24 (16.3%) required reintervention, and target vessel patency was exhibited in 118 (80.2%) patients. The modal endovascular duration was 100–150 min (in 64.6%, n = 95 cases). Analysis revealed that endovascular duration was associated with a lower likelihood of reintervention at 30 days, 6-, and 12 months (P = 0.011, P = 0.019, P = 0.037), a greater likelihood of target vessel patency at 6- and 24 months (P = 0.032, P = 0.035). No relationship between endovascular duration and DS was revealed.DiscussionThe data demonstrates that RELAY™ Branched is associated with promising clinical outcomes for on-label aortic arch TEVAR. The underlying mechanism linking endovascular duration and reintervention rates, or target vessel patency is likely multifactorial and complex. Given that TEVAR is carried out under general anesthetic only, it is unlikely that prolonged procedural duration has any major effect over neurological outcomes for arch TEVAR.

Funder

Royal Society

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3