Feasibility and Accuracy of a Fully Automated Right Ventricular Quantification Software With Three-Dimensional Echocardiography: Comparison With Cardiac Magnetic Resonance

Author:

Ahmad Ashfaq,Li He,Wan Xiaojing,Zhong Yi,Zhang Yanting,Liu Juanjuan,Gao Ying,Qian Mingzhu,Lin Yixia,Yi Luyang,Zhang Li,Li Yuman,Xie Mingxing

Abstract

Background: A novel, fully automated right ventricular (RV) software for three-dimensional quantification of RV volumes and function was developed. The direct comparison of the software performance with cardiac magnetic resonance (CMR) was limited. Therefore, the aim of this study was to test the feasibility, accuracy, and reproducibility of a fully automated RV quantification software against CMR imaging as a reference.Methods: A total of 170 patients who underwent both CMR and three-dimensional echocardiography were enrolled. RV end-diastolic volume (RVEDV), RV end-systolic volume (RVESV), and RV ejection fraction (RVEF) were obtained using fully automated three-dimensional RV quantification software and compared with a CMR reference. For inter-technical agreement, Spearman correlation and Bland–Altman analysis were used.Results: The fully automated RV quantification software was feasible in 149 patients. RVEDV and RVESV were underestimated, and RVEF was overestimated compared with CMR values. RV measurements obtained from the manual editing method correlated better with CMR values than that without manual editing (RVEDV, 0.924 vs. 0.794: RVESV, 0.955 vs. 0.854; RVEF, 0.941 vs. 0.781 respectively, all p < 0.0001) with less bias and narrower limit of agreement (LOA). The bias and LOA for RV volumes and EF using the automated software without and with manual editing were greater in patients with severely impaired RV function or low frame rate than those with normal and mild impaired RV function, or high frame rate. The fully automated RV three-dimensional measurements were highly reproducible.Conclusion: The novel fully automated RV software shows good feasibility and reproducibility, and the measurements had a high correlation with CMR values. These findings support the routine application of the novel 3D automated RV software in clinical practice.

Funder

Fundamental Research Funds for the Central Universities

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3