Author:
Zareef Rana,Anka Mariam,Hatab Taha,El Rassi Issam,Yunis Khalid,Bitar Fadi,Arabi Mariam
Abstract
BackgroundPeripherally inserted central catheters (PICC) are frequently used in neonatal intensive care units (NICU) to assist premature and critically ill neonates. Massive pleural effusions, pericardial effusions, and cardiac tamponade secondary to PICC are extremely uncommon but have potentially fatal consequences.ObjectiveThis study investigates the incidence of tamponade, large pleural, and pericardial effusions secondary to peripherally inserted central catheters in a neonatal intensive care unit at a tertiary care center over a 10-year period. It explores possible etiologies behind such complications and suggests preventative measures.Study designRetrospective analysis of neonates who were admitted to the NICU at the AUBMC between January 2010 and January 2020, and who required insertion of PICC. Neonates who developed tamponade, large pleural, or pericardial effusions secondary to PICC insertion were investigated.ResultsFour neonates developed significant life-threatening effusions. Urgent pericardiocentesis and chest tube placement were required in two and one patients, respectively. No fatalities were encountered.ConclusionThe abrupt onset of hemodynamic instability without an obvious cause in any neonate with PICC in situ should raise suspicion of pleural or pericardial effusions. Timely diagnosis through bedside ultrasound, and prompt aggressive intervention are critical.
Subject
Cardiology and Cardiovascular Medicine
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献