Author:
Dietrich Maximilian,Antonovici Ana,Hölle Tobias,Nusshag Christian,Kapp Anne-Christine,Studier-Fischer Alexander,Arif Rawa,Nickel Felix,Weigand Markus Alexander,Frey Norbert,Lichtenstern Christoph,Leuschner Florian,Fischer Dania
Abstract
IntroductionKidney dysfunction is common in patients with aortic stenosis (AS) and correction of the aortic valve by transcatheter aortic valve implantation (TAVI) often affects kidney function. This may be due to microcirculatory changes.MethodsWe evaluated skin microcirculation with a hyperspectral imaging (HSI) system, and compared tissue oxygenation (StO2), near-infrared perfusion index (NIR), tissue hemoglobin index (THI) and tissue water index (TWI) in 40 patients undergoing TAVI versus 20 control patients. HSI parameters were measured before TAVI (t1), directly after TAVI (t2), and on postinterventional day 3 (t3). The primary outcome was the correlation of tissue oxygenation (StO2) to the creatinine level after TAVI.ResultsWe performed 116 HSI image recordings in patients undergoing TAVI for the treatment of severe aortic stenosis and 20 HSI image recordings in control patients. Patients with AS had a lower THI at the palm (p = 0.034) and a higher TWI at the fingertips (p = 0.003) in comparison to control patients. TAVI led to an increase of TWI, but had no uniform enduring effect on StO2 and THI. Tissue oxygenation StO2 at both measurement sites correlated negatively with creatinine levels after TAVI at t2 (palm: ρ = −0.415; p = 0.009; fingertip: ρ = −0.519; p < 0.001) and t3 (palm: ρ = −0.427; p = 0.008; fingertip: ρ = −0.398; p = 0.013). Patients with higher THI at t3 reported higher physical capacity and general health scores 120 days after TAVI.ConclusionHSI is a promising technique for periinterventional monitoring of tissue oxygenation and microcirculatory perfusion quality, which are related to kidney function, physical capacity, and clinical outcomes after TAVI.Clinical trial registrationhttps://drks.de/search/de/trial, identifier DRKS00024765.
Funder
Deutsche Stiftung für Herzforschung
Subject
Cardiology and Cardiovascular Medicine
Reference27 articles.
1. Post-procedural hypertension following transcatheter aortic valve implantation: incidence and clinical significance.;Perlman;JACC Cardiovasc Interv.,2013
2. Acute kidney injury after aortic valve replacement: incidence, risk factors and outcomes.;Najjar;Expert Rev Cardiovasc Ther.,2015
3. Development and validation of a risk prediction model for in-hospital mortality after transcatheter aortic valve replacement.;Edwards;JAMA Cardiol.,2016
4. Fixing the valve, but injuring the kidneys, with transcatheter aortic valve replacement: collateral damage with serious consequences.;Lindman;JACC Cardiovasc Interv.,2017
5. Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic valve replacement.;Bagur;Eur Heart J.,2010
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献