A Multicenter Randomized Trial Assessing ZENFlow Carrier-Free Drug-Coated Balloon for the Treatment of Femoropopliteal Artery Lesions

Author:

Ni Leng,Ye Wei,Zhang Lan,Jin Xing,Shu Chang,Jiang Jin-song,Yang Mu,Wu Dan-ming,Li Ming,Yu Guan-feng,Yang Jun,Huang Jian-hua,Wang Xiao-bai,Li Xiao-qiang,Jiang Wei-liang,Wu Zhi-qun,Liu Chang-wei

Abstract

Backgrounds and ObjectivesDrug-coated balloons (DCBs) have shown promising benefits in improving the outcomes for patients with peripheral artery disease. Several randomized clinical trials have reported that paclitaxel-coated balloon significantly reduce the rates of restenosis and the need for reintervention in comparison with regular balloon angioplasty. Due to the differences in excipients, paclitaxel dose, and coating techniques, variable clinical outcomes have been observed with different DCBs. In this study, we aimed to evaluate the safety and efficacy of a novel ZENFlow carrier-free DCB in the treatment of femoropopliteal artery occlusive disease.MethodsIn this randomized controlled trial conducted at 15 sites, 192 patients with Rutherford class 3–5 were randomly assigned into two groups: drug-coated balloon group and percutaneous transluminal angioplasty group. The primary endpoint was a late lumen loss at 6 months based on blinded angiographic core laboratory evaluations, and the secondary endpoints included primary patency rate, binary restenosis, clinically driven target lesion revascularization, ankle-brachial index, Rutherford class change, and major adverse events.ResultsIn this multicenter trial, 93 patients received DCB angioplasty, whereas 99 patients underwent regular balloon angioplasty. The late lumen loss at 6-month follow-up was 0.50 ± 0.82 and 1.69 ± 0.87 mm in the drug-coated balloon and percutaneous transluminal angioplasty groups, respectively (p < 0.001). During the 12-month follow-up period, the drug-coated balloon group showed a significantly higher primary patency rate (54 vs. 31.3%, p = 0.009) and markedly lower rates of target vessel restenosis (22.1 vs. 64.3%, p < 0.001) and clinically driven target lesion revascularization rate (5.4 vs. 19.2%, p = 0.006) than the percutaneous transluminal angioplasty group. Compared with the percutaneous transluminal angioplasty group, the drug-coated balloon group had significant improvements in the ankle-brachial index and Rutherford class. The all-cause mortality rate was comparable, and no device-related deaths occurred in either groups.ConclusionsBalloon angioplasty using a ZENFlow carrier-free drug-coated balloon is a safe and effective treatment method for femoropopliteal artery lesions. This novel drug-coated balloon catheter achieved satisfactory early and 1-year outcomes in this trial.Clinical Trial Registrationhttps://clinicaltrials.gov, identifier: NCT03844724.

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3