Vasodilator Myocardial Perfusion Cardiac Magnetic Resonance Imaging Is Superior to Dobutamine Stress Echocardiography in the Detection of Relevant Coronary Artery Stenosis: A Systematic Review and Meta-Analysis on Their Diagnostic Accuracy

Author:

Haberkorn Sebastian M.,Haberkorn Sandra I.,Bönner Florian,Kelm Malte,Hopkin Gareth,Petersen Steffen E.

Abstract

Objectives: Guideline recommendations for patients with either a high or a low risk of obstructive coronary artery disease (CAD) are clear. However, the evidence for initial risk stratification in patients with an intermediate risk of CAD is still unclear, despite the availability of multiple non-invasive assessment strategies. The aim of this study was to synthesize the evidence for this population to provide more informed recommendations.Background: A meta-analysis was performed to systematically assess the diagnostic accuracy of vasodilator myocardial perfusion cardiovascular magnetic resonance imaging (pCMR) and dobutamine stress echocardiography (DSE) for the detection of relevant CAD. In contrast to previous work, this meta-analysis follows rigorous selection criteria in regards to the risk stratification and a narrowly prespecified definition of their invasive reference tests, resulting in unprecedentedly informative results for this reference group.Data Collection and Analysis: From the 5,634 studies identified, 1,306 relevant articles were selected after title screening and further abstract screening left 865 studies for full-text review. Of these, 47 studies fulfilled all inclusion criteria resulting in a total sample size of 4,742 patients.Results: pCMR studies showed a superior sensitivity [0.88 (95% confidence interval (CI): 0.85–0.90) vs. 0.72 (95% CI: 0.61–0.81)], diagnostic odds ratio (DOR) [38 (95% CI: 29–49) vs. 20 (95% CI: 9–46)] and an augmented post-test probability [negative likelihood ratio (LR) of 0.14 (95% CI: 0.12–0.18) vs. 0.31 (95% CI: 0.21, 0.46)] as compared to DSE. Specificity was statistically indifferent [0.84 (95% CI: 0.81–0.87) vs. 0.89 (95% CI: 0.83–0.93)].Conclusion: The results of this systematic review and meta-analysis suggest that pCMR has a superior diagnostic test accuracy for relevant CAD compared to DSE. In patients with intermediate risk of CAD only pCMR can reliably rule out relevant stenosis. In this risk cohort, pCMR can be offered for initial risk stratification and guidance of further invasive treatment as it also rules in relevant CAD.

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3