Deep vein thrombosis and pulmonary embolism: a prospective, observational study to evaluate diagnostic performance of the Tina-quant D-Dimer Gen.2 assay

Author:

Bertsch Thomas,Behringer Wilhelm,Blaschke Sabine,Body Richard,Davidson Simon,Müller-Olling Mirco,Guo Ge,Rieger Anna,Wahl Annika,Horner Daniel,Sun Yuli,Turnes Lucia,Sonner Ulrich,Hoffmann Michael

Abstract

BackgroundD-Dimer testing is a diagnostic tool for exclusion of deep vein thrombosis (DVT) and pulmonary embolism (PE). This study evaluated the diagnostic performance of the Tina-quant® D-Dimer Gen.2 assay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) in patients with low/intermediate pre-test probability of DVT/PE using standard, age-, and clinical probability-adjusted cut-offs.MethodsIn this prospective, observational, multicenter study (July 2017–August 2019), plasma samples were collected from hospital emergency departments and specialist referral centers. DVT/PE was diagnosed under hospital standard procedures and imaging protocols. A standard D-dimer cut-off of 0.5 µg fibrinogen equivalent units (FEU)/ml was combined with the three-level Wells score; cut-offs adjusted for age (age × 0.01 µg FEU/ml for patients >50 years) and clinical probability (1 µg FEU/ml for low probability) were also evaluated. An assay comparison was conducted in a subset of samples using the Tina-quant D-Dimer Gen.2 assay and the previously established routine laboratory assay, STA-Liatest D-Di Plus assay (Stago Deutschland GmbH, Düsseldorf, Germany).Results2,897 patients were enrolled; 2,516 completed the study (DVT cohort: 1,741 PE cohort: 775). Clinical assessment plus D-dimer testing using the standard cut-off resulted in 317 (DVT) and 230 (PE) false positives, and zero (DVT) and one (PE) false negatives. Negative predictive value (NPV) was 100.0% (95% confidence interval [CI]: 99.7%–100.0%) and 99.8% (95% CI: 98.8%–100.0%) for DVT and PE, respectively. After age-adjustment, NPV was 99.9% (95% CI: 99.6%–100.0%) and 99.1% (95% CI: 97.8–99.7) for DVT and PE, respectively. False positive rates decreased (>50%) in clinical probability-adjusted analyses vs. primary analysis. In the assay comparison, the performances of the two assays were comparable.ConclusionThe Tina-quant D-Dimer Gen.2 assay and standard D-dimer cut-off level combined with the three-level Wells score accurately identified patients with a very low probability of DVT/PE.

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3