Transcatheter aortic valve replacement with the VenusA-Pro and VenusA-Plus systems: preliminary experience in China

Author:

Li Jie,Sun Yinghao,Luo Songyuan,Zheng Shengneng,Chen Jiaohua,Fu Ming,Fang Zhenfei,Wang Yan,Li Guang,Fan Ruixin,Luo Jianfang

Abstract

BackgroundThe outcomes of transcatheter aortic valve replacement (TAVR) employing the second-generation retrievable VenusA-Pro and VenusA-Plus delivery systems with the self-expanding VenusA-Valve have not been described yet. This study aims to report the outcomes of these two second-generation delivery systems.MethodsFrom January 2022 to April 2023, we prospectively enrolled patients with severe aortic stenosis undergoing TAVR with VenusA-Pro from three centers across China in this first-in-man study and retrospectively identified those undergoing TAVR with VenusA-Plus. All outcomes were reported according to the Valve Academic Research Consortium 3 definition. The primary outcome was 30-day all-cause mortality.ResultsA total of 156 patients were included, of which 46 underwent TAVR with VenusA-Pro and 110 underwent TAVR with VenusA-Plus. The Society of Thoracic Surgeons median score was 2.1%, bicuspid anatomy prevalence rate was 55.1%, and the mean aortic root calcification volume was 693 mm3. The technical success rate was 91.7%, comparable between the VenusA-Pro and VenusA-Plus groups (87.0% vs. 93.6%, P = 0.169). The 30-day all-cause mortality was 2.6%, similar between the VenusA-Pro and VenusA-Plus groups (2.2% vs. 2.7%, P = 0.842). No myocardial infarction occurred. The incidences of stroke (0.6%), major bleeding (3.8%), major vascular complications (5.1%), acute kidney injury (9.0%), permanent pacemaker implantation (5.1%), new-onset atrial fibrillation (5.8%), and moderate-to-severe paravalvular aortic regurgitation (6.0%) were favorable and comparable between the two groups. The clinical outcomes were similar between the patients with bicuspid and tricuspid aortic valve, except that the incidence of permanent pacemaker implantation was lower in patients with bicuspid anatomy (1.2% vs. 10.6%, P = 0.010).ConclusionsThe 30-day outcomes of TAVR with VenusA-Pro and VenusA-Plus were favorable and comparable.

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3