A Perturbed Postural Balance Test Using an Instrumented Treadmill – Precision and Accuracy of Belt Movement and Test-Retest Reliability of Balance Measures

Author:

Lesch Kim J.,Lavikainen Jere,Hyrylä Vesa,Vartiainen Paavo,Venojärvi Mika,Karjalainen Pasi A.,Tikkanen Heikki,Stenroth Lauri

Abstract

A perturbed postural balance test can be used to investigate balance control under mechanical disturbances. The test is typically performed using purpose-built movable force plates. As instrumented treadmills become increasingly common in biomechanics laboratories and in clinical settings, these devices could be potentially used to assess and train balance control. The purpose of the study was to investigate how an instrumented treadmill applies to perturbed postural balance test. This was investigated by assessing the precision and reliability of the treadmill belt movement and the test-retest reliability of perturbed postural balance test over 5 days. Postural balance variables were calculated from the center of pressure trajectory and included peak displacement, time to peak displacement, and recovery displacement. Additionally, the study investigated short-term learning effects over the 5 days. Eight healthy participants (aged 24–43 years) were assessed for 5 consecutive days with four different perturbation protocols. Center of pressure (COP) data were collected using the force plates of the treadmill while participant and belt movements were measured with an optical motion capture system. The results show that the treadmill can reliably deliver the intended perturbations with <1% deviation in total displacement and with minimal variability between days and participants (typical errors 0.06–2.71%). However, the treadmill was not able to reach the programmed 4 m/s2 acceleration, reaching only about 75% of it. Test–retest reliability of the selected postural balance variables ranged from poor to good (ICC 0.156–0.752) with typical errors between 4.3 and 28.2%. Learning effects were detected based on linear or quadratic trends (p < 0.05) in peak displacement of the slow forward and fast backward protocols and in time to peak displacement in slow and fast backward protocols. The participants altered the initial location of the COP relative to the foot depending on the direction of the perturbation. In conclusion, the precision and accuracy of belt movement were found to be excellent. Test-retest reliability of the balance test utilizing an instrumented treadmill ranged from poor to good which is, in line with previous investigations using purpose-built devices for perturbed postural balance assessment.

Publisher

Frontiers Media SA

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3