Decreasing the Weight-Size Parameters of Gas-Steam Turbine Plant by Increasing the Efficiency of Thermodynamic Processes in the Condenser
-
Published:2021-11
Issue:4(52)
Volume:
Page:43-58
-
ISSN:1857-0070
-
Container-title:Problems of the Regional Energetics
-
language:
-
Short-container-title:PRE
Author:
Bortsov Aleksandr, ,Shevtsov Anatoliy,
Abstract
The aim of this work is decreasing the weight-size parameters of the contact gas-steam turbine plant and contact condenser elements by increasing the efficiency of thermal-gas dynamic processes of condensation through rational irrigation of countercurrent gas-steam flow. To achieve the goal the total efficiency of water-return drops ranging from 0.1 to 1 mm at different initial velocities from 5 to 35 m/s emitted by the multi-nozzle sprinkler was determined by mathematical modeling of the liquid droplet movement processes, heat and mass transfer between the liquid droplet and gas-vapor mixture, and gas-vapor mixture pressure loss. The effect of increasing the gas-steam mixture velocity from 3.3 to 6 m/s on the overall efficiency of water return was determined. The novelty of the obtained results was defined by an increase in the water return into cycle from 12 to 13% with a droplet diameter of 0.3 -- 0.4 mm and the initial velocity from the sprinkler of 5--10 m/s. The velocity of the mixture was to 6 m/s at rational correlations of the initial velocity of the droplets’ escape, which increased the total amount of heat withdrawn to 11%. The positive effect conditions of irrigation processes on thermogasdynamic and weight-size parameters of the condenser elements for the contact gas and steam turbine plant at full pressure recovery coefficients of over 0.967 were substantiated. The most significant result was the reduction of the weight-size parameters of the marine infrastructure object power plant from 8 to 19%.
Publisher
Institute of Power Engineering