Computed diffusion-weighted imaging with a low-apparent diffusion coefficient-pixel cut-off technique for breast cancer detection

Author:

Kazama Toshiki1ORCID,Takahara Taro2,Endo Jun1,Yamamuro Hiroshi1,Sekiguchi Tatsuya1,Niwa Tetsu1,Niikura Naoki3,Okamura Takuho3,Kumaki Nobue4,Hashimoto Jun1

Affiliation:

1. Department of Diagnostic Radiology, Tokai University School of Medicine, Isehara, Japan

2. Department of Biomedical Engineering, Tokai University School of Engineering, Hiratsuka, Japan

3. Department of Breast Oncology, Tokai University School of Medicine, Isehara, Japan

4. Department of Pathology, Tokai University School of Medicine, Isehara, Japan

Abstract

Objective: This study aimed to compare the image quality and diagnostic performance of computed diffusion-weighted imaging (DWI) with low-apparent diffusion coefficient (ADC)-pixel cut-off technique (cDWI cut-off) and actual measured DWI (mDWI). Methods: Eighty-seven consecutive patients with malignant breast lesions and 72 with negative breast lesions who underwent breast MRI were retrospectively evaluated. Computed DWI with high b-values of 800, 1200, and 1500 s/mm2 and ADC cut-off thresholds of none, 0, 0.3, and 0.6 (×10−3 mm2/s) were generated from DWI with two b-values (0 and 800 s/mm2). To identify the optimal conditions, two radiologists evaluated the fat suppression and lesion reduction failure using a cut-off technique. The contrast between breast cancer and glandular tissue was evaluated using region of interest analysis. Three other board-certified radiologists independently assessed the optimised cDWI cut-off and mDWI data sets. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis. Results: When an ADC cut-off threshold of 0.3 or 0.6 (× 10−3 mm2/s) was applied, fat suppression improved significantly (p < .05). The contrast of the cDWI cut-off with a b-value of 1200 or 1500 s/mm2 was better than the mDWI (p < .01). The ROC area under the curve for breast cancer detection was 0.837 for the mDWI and 0.909 for the cDWI cut-off (p < .01). Conclusion: The cDWI cut-off provided better diagnostic performance than mDWI for breast cancer detection. Advances in knowledge: Using the low-ADC-pixel cut-off technique, computed DWI can improve diagnostic performance by increasing contrast and eliminating un-suppressed fat signals.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3