The clinical value of conventional ultrasound combined with contrast-enhanced ultrasound in the evaluation of BI-RADS 4 lesions detected by magnetic resonance imaging

Author:

Guo Wenjuan1,Li Fan1,Jia Chao1,Wang Tong1,Zhang Xuemei2,Yao Gehong3,Shi Xiudong3,Bai Min1

Affiliation:

1. Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

2. Department of Pathology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

3. Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

Abstract

Objective To determine the value of conventional ultrasound combined with contrast-enhanced ultrasound (CEUS) in Breast Imaging Reporting and Data System (BI-RADS) Category 4 lesions as detected by MRI. Methods A total of 176 breast lesions from 171 patients were detected by MRI and categorised as BI-RADS 4. All patients also underwent ultrasound and CEUS scans. The combination of ultrasound-BI-RADS and CEUS 5-point scoring system created the Rerated BI-RADS (referred to as CEUS-BI-RADS). The diagnostic performances of ultrasound and CEUS-BI-RADS were then compared. A χ2 test was used to compare the CEUS features of mass-like and non-mass-like enhancement types of MRI-BI-RADS 4 lesions. Results There were 167 (167/176) breast lesions detected by ultrasound, with a detection rate of 94.89%, while all were subsequently detected by “second-look” ultrasound combined with CEUS, with a detection rate of 100%. The areas under the receiver operating characteristic curves for ultrasound and CEUS-BI-RADS were 0.810 and 0.940, respectively. The diagnostic efficiency of CEUS-BI-RADS was significantly higher than that of ultrasound alone (z = 3.264, p = 0.001). For both mass-like and non-mass-like enhancement types of MRI-BI-RADS 4 lesions, CEUS-BI-RADS demonstrated satisfactory sensitivity and accuracy. Moreover, 29 (29/176) category 4 lesions were downgraded to 3 by CEUS-BI-RADS. Conclusion Ultrasound combined with CEUS can allow reclassification, reduce biopsy rates, and facilitate pre-surgical localisation for biopsy or surgery for MRI-BI-RADS 4 lesions. Advances in knowledge For MRI-BI-RADS Category 4 lesions with a wide range of malignancies, ultrasound combined with CEUS is a promising diagnostic approach with high clinical utility.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3