The kinetic quantitative characteristics of non-mass breast lesions with contrast-enhanced ultrasound: a prospective study

Author:

Cai Ying-Yu1,Du Yi-Chao2,Zhao Lei1,Hu Wen-Jie3,Bai Yun1,Chen An4,Du Lian-Fang1,Li Fan1

Affiliation:

1. Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai, China

2. Department of Neurosurgery, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai, China

3. Department of Ultrasound, Huashan Hospital, Fudan University , Shanghai, China

4. Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai, China

Abstract

Objective To characterize non-mass breast lesions (NML) quantitatively by contrast-enhanced ultrasound (CEUS) and to evaluate its additional diagnostic value based on the Breast Imaging Reporting and Data System (BI-RADS) categories. Methods A prospective study was performed among consecutive patients with NMLs. All lesions were examined by grayscale ultrasound and CEUS and diagnosed on pathology. Standard mammograms were obtained in the patients over 30 years old. Three independent radiologists assessed the features on grayscale ultrasound and mammograms and classified NMLs according to BI-RADS categories. Combined with the quantitative analysis in CEUS, the BI-RADS categories were reassessed, and the sensitivity, specificity, positive-predictive value, negative-predictive value and area under the receiver operating characteristic curve (AUC) were calculated for the evaluation of the diagnostic performance. Results: 30 benign and 24 malignant NMLs were finally enrolled in this study, with ductal carcinoma in situ being the majority of malignant (15/24). Average contrast signal intensity (AI), wash-in rate (WiR) and enhancement intensity at 40 s (I40) were found to be the most efficient kinetic parameters to diagnose malignant NMLs. Combined with the cut-off values of 205.2 for AI, 127.8 for WiR and 136.4 for I40, the diagnostic accuracy was improved (AUC = 0.904), with the sensitivity of 95.8% and the specificity of 70.0%. Conclusion The results suggested that hyperenhancement and rapid wash-in and wash-out are the characteristics of malignant NMLs. The kinetic analysis using CEUS can reflect hypervascular nature of malignant NMLs, thus improving the diagnostic performance combined with grayscale ultrasound. Advances in knowledge: In this study, we quantified the enhancement characteristics of non-mass breast lesions with CEUS. We revealed that the combination of CEUS and conventional ultrasound provided higher sensitivity for diagnosing malignant NMLs.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3