Determination of a cone-beam CT low-dose protocol for root fracture diagnosis in non-endodontically treated anterior maxillary teeth

Author:

Andraws Yalda Fedil12ORCID,Theodorakou Chrysoula3,Clarkson Rosalyn J4,Davies Jonathan5,Feinberg Lee6,Sengupta Anita2,Horner Keith2

Affiliation:

1. College of Dentistry, Hawler Medical University, Erbil, Iraq

2. Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine andHealth, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK

3. Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK

4. Department of Radiology, Leeds Dental Institute, Clarendon Way, Leeds, UK

5. Department of Dental Radiological Imaging, Guy's and St Thomas' NHS FoundationTrust, Guy's Hospital, London, UK

6. Department of Radiology, Kings College Hospital, London, UK

Abstract

Objectives: The aim of this study was to determine a “low-dose protocol” which provides acceptable diagnostic accuracy for detection of root fractures in unrestored anterior maxillary teeth, using an ex vivo model. Methods: 48 maxillary anterior teeth, half with horizontal or oblique root fractures, were imaged using CBCT in an anthropomorphic model. Nine X-ray exposure combinations were used, including the manufacturer’s standard (“reference”) exposure and high-resolution settings (“HiRes”), by varying kV, exposure time, and rotation angle. Measurements of Dose Area Product (DAP) were recorded. Five dental radiologists assessed the scans for root fractures and judged image quality. Parameters of diagnostic accuracy were calculated, including area under the Receiver Operating Characteristic curve (Az). Objective measures of image quality were made at the same exposure combinations using an image quality phantom. Results: Although there was a significant linear relationship between DAP and mean Az, only the lowest DAP exposure combination had a mean Az significantly different to the reference exposure. There was no significant effect on other diagnostic accuracy parameters when using HiRes compared with the reference exposure. There was a significant positive relationship between DAP and contrast resolution. HiRes did not significantly improve contrast resolution and made a small improvement to spatial resolution. Conclusions: Scope existed for radiation dose reduction compared with the manufacturer’s guidance. There was no improvement in diagnostic accuracy using HiRes settings. A cautious recommendation for this CBCT machine is that it is possible to achieve a dose reduction of about 20% compared with the reference exposure parameters.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3