Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures

Author:

Caetano Aline PF1,Sousa Thiago O2,Oliveira Mariana R1,Evanglista Karine1,Bueno Juliano M3,Silva Maria AG1

Affiliation:

1. Faculty of Dentistry, Federal University of Goiás, Goiânia, Goiás, Brazil

2. Private Practioner, Goiânia, Goiás, Brazil

3. São Leopoldo Mandic, Private Practioner, Goiânia, Goiás, Brazil

Abstract

Objectives : The aim of this study was to compare the accuracy of vertical root fracture (VRF) detection using three tomography devices and two software systems in teeth with different endodontic fillings. Methods: The sample consisted of 45 premolars divided into 3 groups: No filling (NF, n=15); Gutta percha (GP, n=15) and Metallic Post (MP, n=15). Cone-beam computed tomography (CBCT) images were acquired in Kodak 9000 3D, Orthopantomography 300 (OP300) and PreXion 3D devices, before and after induced root fractures. Two oral radiologists analyzed all images using InVivoDental and e-Vol DX software systems. The analysis was repeated after 15 days in 30% of the sample. Data analysis compared receiver operating characteristic (ROC) curves, as well the areas under the ROC curves. Accuracy, sensitivity, specificity, positive and negative predictive value were calculated according to each tomographic device and software. Intra- and interexaminer reliability were tested using the Kappa coefficient. Results: The highest accuracy was seen in the image set from the PreXion 3D, using InVivo (0.96) or e-Vol DX (0.92) in image analysis. The OP300 device presented a similar performance of the PreXion 3D in teeth with different endodontic fillings. When using e-Vol DX, the accuracy of Kodak 9000 3D improved from 0.62 to 0.74. Conclusions: The PreXion 3D device is the most accurate when detecting VRF, with a performance similar to the OP300 in endodontic filled teeth. Kodak 9000 3D is indicated for teeth without fillings, with better accuracy using e-Vol DX software.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3