MR lymphography with superparamagnetic iron oxide for sentinel lymph node mapping of N0 early oral cancer: A pilot study

Author:

Sugiyama Satomi1,Iwai Toshinori1,Baba Junichi1,Oguri Senri1,Izumi Toshiharu2,Sekino Masaki3,Kusakabe Moriaki45,Mitsudo Kenji1

Affiliation:

1. Department of Oral and Maxillofacial Surgery/Orthodontics, Yokohama City University hospital, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa, Japan

2. Department of Radiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-ku, Yokohama, Kanagawa, Japan

3. Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan

4. Research Center for Food Safety, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan

5. Department of Medical Device, Matrix Cell Research Institute Inc, Ushiku, Ibaraki, Japan

Abstract

Objectives: The purpose of this pilot study was to evaluate the usefulness of magnetic resonance lymphography (MRL) with superparamagnetic iron oxide (SPIO) in sentinel lymph node (SLN) mapping of clinically N0 early oral cancer, and to conduct a comparative study of this MRL with CT lymphography (CTL). Methods: CTL and MRL were performed for SLN mapping before surgery for 20 patients with clinically N0 early oral cancer. The detection rate, number, and location of SLNs in CTL and MRL were evaluated. Furthermore, optimal scanning/imaging timing in MRL was examined. Results: SLNs were detected by CTL in 18 (90%) patients, and the total and mean number of SLN were 35 and 1.8, respectively. All SLNs could be detected 2 min and 3.5–5 min after contrast medium injection. In all patients, SLNs were detected by MRL at 10 min after SPIO injection, and the total and mean number of SLN was 53 and 2.7, respectively. MRL at 30 min after the injection showed additional 18 secondary lymph nodes. Conclusion: MRL with SPIO is safe and useful imaging for the detection of SLNs in clinically N0 early oral cancer, and the optimal imaging timing is 10 min after SPIO injection.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3