Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models

Author:

van Eijnatten Maureen1,Wolff Jan2,Pauwels Ruben34,Karhu Kalle5,Hietanen Ari6,der Sarkissian Henry7,Koivisto Juha H8

Affiliation:

1. Department of Oral and Maxillofacial Surgery/Oral Pathology, 3D Innovation Lab, Amsterdam UMC (location: VUmc), Amsterdam, The Netherlands

2. Department of Dentistry and Oral Health Section of Oral and Maxillofacial Surgery and Oral Pathology, Aarhus University Vennelyst Boulevard , Aarhus C, Denmark

3. Aarhus Institute of Advanced Studies Aarhus University Høegh-Guldbergs Gade 6B, Aarhus, Denmark

4. Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand

5. Varjo Oy Vuorikatu 20, FIN-00100, Helsinki, Finland

6. Planmeca Oy Asentajankatu 6, FIN-00880, Helsinki, Finland

7. Centrum Wiskunde & Informatica, Amsterdam, The Netherlands

8. Department of Physics, University of Helsinki Gustaf Hällströmin katu 2, Helsinki, Finland

Abstract

Objective: Cone beam computed tomography (CBCT) images are being increasingly used to acquire three-dimensional (3D) models of the skull for additive manufacturing purposes. However, the accuracy of such models remains a challenge, especially in the orbital area. The aim of this study is to assess the impact of four different CBCT imaging positions on the accuracy of the resulting 3D models in the orbital area. Methods: An anthropomorphic head phantom was manufactured by submerging a dry human skull in silicon to mimic the soft tissue attenuation and scattering properties of the human head. The phantom was scanned on a ProMax 3D MAX CBCT scanner using 90 and 120 kV for four different field of view positions: standard; elevated; backwards tilted; and forward tilted. All CBCT images were subsequently converted into 3D models and geometrically compared with a “gold-standard” optical scan of the dry skull. Results: Mean absolute deviations of the 3D models ranged between 0.15 ± 0.11 mm and 0.56 ± 0.28 mm. The elevated imaging position in combination with 120 kV tube voltage resulted in an improved representation of the orbital walls in the resulting 3D model without compromising the accuracy. Conclusions: Head positioning during CBCT imaging can influence the accuracy of the resulting 3D model. The accuracy of such models may be improved by positioning the region of interest (e.g. the orbital area) in the focal plane ( Figure 2a ) of the CBCT X-ray beam.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3