Multifrequency magnetic resonance elastography-based tomoelastography of the parotid glands–feasibility and reference values

Author:

Elsholtz Fabian Henry Jürgen1ORCID,Reiter Rolf12,Marticorena Garcia Stephan Rodrigo3,Braun Jürgen4,Sack Ingolf3,Hamm Bernd1,Schaafs Lars-Arne1

Affiliation:

1. Department of Radiology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Campus Benjamin Franklin, Berlin, Germany

2. Berlin Institute of Health at Charité – Universitätsmedizin Berlin, Berlin, Germany

3. Department of Radiology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Campus Charité Mitte, Berlin, Germany

4. Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Medical Informatics, Campus Charité Mitte, Berlin, Germany

Abstract

Objectives: Accurate radiological differentiation of parotid tumors remains challenging despite recent technical advances in quantitative medical imaging. Multifrequency magnetic resonance elastography (MRE) could provide additional information on viscoelastic properties of normal and abnormal biological tissues. This study investigates the feasibility of MRE of the parotid glands in healthy participants and provides first reference values. Methods: 20 healthy participants underwent multifrequency MRE of both parotid glands at 3 Tesla. Shear waves at frequencies of 25, 30, 40, and 50 Hz were introduced into the participants' heads through the occiput using pressurized-air actuators. Shear wave speed (SWS) and loss angle of the shear modulus (φ) were reconstructed by tomoelastography post-processing as surrogate parameters for tissue stiffness and viscosity or fluidity. 10 participants underwent repeated MRE to determine test–retest reliability based on intraclass correlation coefficients. Results: All MRE datasets acquired could be included in the analysis. Mean SWS was 0.97 ± 0.13 m/s, and mean φ was 0.59 ± 0.05 rad, each for both sides combined and without notable lateral difference (p = 0.88/0.87). Test–retest reliability was good for SWS (ICC = 0.84 for both sides/ICC = 0.77 for the right side/ICC = 0.79 for the left side) and good to excellent for φ(ICC = 0.94/0.86/0.90). Conclusions: Multifrequency MRE of the parotid glands is feasible and reliable. This technique, therefore, is a promising method for investigating the viscoelastic properties of salivary gland tumors in future studies.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3