Comparison of five convolutional neural networks for predicting osteoporosis based on mandibular cortical index on panoramic radiographs

Author:

Tassoker Melek1ORCID,Öziç Muhammet Üsame2,Yuce Fatma3

Affiliation:

1. Department of Oral and Maxillofacial Radiology, Necmettin Erbakan University Faculty of Dentistry, Konya, Turkey

2. Department of Biomedical Engineering, Pamukkale University, Faculty of Technology, Denizli, Turkey

3. Department of Oral and Maxillofacial Radiology, Okan University, Istanbul, Turkey

Abstract

Objectives: The aim of the present study was to compare five convolutional neural networks for predicting osteoporosis based on mandibular cortical index (MCI) on panoramic radiographs. Methods: Panoramic radiographs of 744 female patients over 50 years of age were labeled as C1, C2, and C3 depending on the MCI. The data of the present study were reviewed in different categories including (C1, C2, C3), (C1, C2), (C1, C3), and (C1, (C2 +C3)) as two-class and three-class predictions. The data were separated randomly as 20% test data, and the remaining data were used for training and validation with fivefold cross-validation. AlexNET, GoogleNET, ResNET-50, SqueezeNET, and ShuffleNET deep-learning models were trained through the transfer learning method. The results were evaluated by performance criteria including accuracy, sensitivity, specificity, F1-score, AUC, and training duration. The Gradient-Weighted Class Activation Mapping (Grad-CAM) method was applied for visual interpretation of where deep-learning algorithms gather the feature from image regions. Results: The dataset (C1, C2, C3) has an accuracy rate of 81.14% with AlexNET; the dataset (C1, C2) has an accuracy rate of 88.94% with GoogleNET; the dataset (C1, C3) has an accuracy rate of 98.56% with AlexNET; and the dataset (C1,(C2+C3)) has an accuracy rate of 92.79% with GoogleNET. Conclusion: The highest accuracy was obtained in the differentiation of C3 and C1 where osseous structure characteristics change significantly. Since the C2 score represent the intermediate stage (osteopenia), structural characteristics of the bone present behaviors closer to C1 and C3 scores. Therefore, the data set including the C2 score provided relatively lower accuracy results.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3