An analysis of patient dose received during cone-beam computed tomography in relation to scan settings and imaging indications as seen in a dental institution in order to establish institutional diagnostic reference levels

Author:

Hung Kuo Feng12,Hui Liuling12,Yeung Andy Wai Kan1,Jacobs Reinhilde3,Leung Yiu Yan2,Bornstein Michael M.14

Affiliation:

1. Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

2. Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

3. OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven and Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium

4. Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland

Abstract

Objectives: To investigate the dose-area product (DAP) of cone-beam computed tomography (CBCT) examinations for different scan settings and imaging indications, and to establish institutional diagnostic reference levels (DRLs) for dose optimisation. Methods: A retrospective analysis of the DAP values of 3568 CBCT examinations taken from two different devices at the Prince Philip Dental Hospital, Hong Kong between 2016 and 2021 was performed. Patient- (age, gender, and imaging indication) and imaging-related (CBCT device, field-of-view (FOV), and voxel size) were correlated with the DAPs. The indication-oriented third-quartile DAP values were compared with DRLs from the UK, Finland, and Switzerland. The obtained third-quartile DAPs lower than the national DRLs and those for which no national DRLs have been proposed were used to establish institutional DRLs. Results: In the investigated CBCTs, the DAP value for large FOV scans was significantly lower than medium/small FOVs. CBCTs with a small voxel size exhibited a significantly higher DAP than those with a medium/large voxel size. CBCTs for endodontic, periodontal, orthodontic, or orthognathic evaluation exhibited a significantly higher DAP than other indications. Twelve indication-oriented institutional DRLs were established and five of them were lower than the national DRLs: third molars (229 mGy×cm2), jaw cysts/tumours (410 mGy×cm2), maxillary sinus pathology (520 mGy×cm2), developing dentition (164 mGy×cm2), and periapical lesions (564 mGy×cm2). Conclusions: CBCT examinations for endodontic, periodontal, orthodontic, or orthognathic evaluation may deliver a higher radiation dose to the patient than other imaging tasks. A periodic review of the patient dose from CBCT imaging and establishment of institutional DRLs for specific clinical settings are needed for monitoring patient dose and to optimise indication-oriented scanning protocols.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3