Quantitative assessment of condylar bone resorption using fused CBCT images: differentiating and diagnosing three distinct groups based on volume and thickness decrease

Author:

Feng Ji-ling1,Ma Ruo-han1,Sun Li-li1,Zhao Jun-ru1,Zhao Yan-ping12,Li Gang1

Affiliation:

1. Department of Oral and Maxillofacial Radiology, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Device & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials , Beijing, China

2. Center for Temporomandibular Disorders and Orofacial Pain, Peking University School and Hospital of Stomatology , Beijing, China

Abstract

Objectives To investigate the accuracy of fused CBCT images in diagnosing three distinct groups of bone changes characterized by volume and thickness decrease in patients with temporomandibular joint osteoarthrosis (TMJ OA) during follow-up. Methods In this retrospective study, 109 patients (176 TMJs) with TMJ OA were included. Two consecutive CBCT images for the same patient were registered and fused. Then, three image sets were established: without fusion, fused 2D image, and fused 3D image. Three residents randomly and independently evaluated whether there was condylar resorption with the three image sets respectively. The samples diagnosed as condylar resorption by the expert panel were divided into three subgroups according to the volume and thickness decrease calculated after segmentation. The inter- and intraobserver agreement, receiver operating characteristic (ROC), and area under the curve (AUC) evaluated the diagnostic capability for different subgroups. Results For the volume decrease more than 50 mm3 and thickness decrease more than 1 mm groups, the AUC values for fused image sets were higher than those without fusion (p < 0.01). For the volume decrease within 50 mm3 and thickness decrease within 1 mm groups, the AUC values for fused 2D image sets were higher than the image sets without fusion (p < 0.05), but there was no significant difference between the fused 3D image sets and the image sets without fusion (p = 0.48 for volume decrease, p = 0.37 for thickness decrease). Conclusions The fused images can improve the diagnostic accuracy and repeatability for the samples with at least 50 mm3 volume decrease or 1 mm thickness decrease compared with the image groups without fusion.

Publisher

Oxford University Press (OUP)

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司