Influence of artefacts generated by titanium and zirconium implants in the study of trabecular bone architecture in cone-beam CT images

Author:

Vitulli Ivana1ORCID,Fontenele Rocharles Cavalcante1ORCID,Nascimento Eduarda Helena Leandro2ORCID,Freitas Deborah Queiroz1ORCID

Affiliation:

1. Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil

2. Department of Dentistry, Division of Oral Radiology, Odontomed Imagem - Medical and Dental Services, Recife, PE, Brazil

Abstract

Objectives: To evaluate the influence of artefacts generated by titanium and zirconium implants on trabecular bone architecture assessment through cone-beam CT (CBCT). The influence of kilovoltage (kVp) and metal artefact reduction (MAR) in such analysis was also assessed. Methods: CBCT scans were obtained with Picasso Trio with or without a titanium or zirconium implants in a posterior region of a mandible using 70, 80 or 90 kVp, with or without MAR. The other acquisition settings were constant: field of view 8 × 5 cm, voxel size 0.2 mm, 5 mA, 24 s and 720 frames. Two volumes of interest (VOIs) were determined comprising trabecular bone mesial and distal to the implant area. The following morphometric parameters were measured: connectivity density (Conn. Dn.), fractal dimension (FD), bone volume fraction (BV/TV), bone surface density (BS/TV), trabecular thickness (Tb. Th.), and trabecular spacing (Tb. Sp.), and compared by multiway ANOVA (α = 0.05). Results: For Conn. Dn. and FD, with MAR, the zirconium group showed values significantly lower than the other groups (p < 0.05). For BV/TV, BS/TV, Tb. Th. and Tb. Sp., the zirconium group showed the highest values, regardless of MAR condition (p < 0.05). MAR increased BS/TV and Tb. Th. values, and decreased FD values for zirconium group. In general, the kVp level did not influence trabecular morphometric parameters. Conclusion: The assessment of the trabecular bone architecture was mainly influenced by the expression of the artefacts generated by zirconium implants. MAR decreased the FD and increased the BS/TV and Tb.Th. values regardless of the kVp level.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3