Liver T1 relaxation time of the ‘normal liver’ in healthy Asians: measurement with MOLLI and B1-corrected VFA methods at 3T

Author:

Ghavamian Armin1ORCID,Liu Cuihong12,Kang Bing2,Yuan Xianshun2,Wang Ximing12,Gao Ling3,Zhao Xinya12

Affiliation:

1. Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Shandong, China

2. Shandong Provincial Hospital Affiliated to Shandong First Medical University, Shandong University, Shandong, China

3. Department of Endocrinology, Shandong Provincial Hospital affiliated to Shandong University, Shandong Clinical Medical Center of Endocrinology and Metabolism, Institute of Endocrinology and Metabolism, Shandong Academy of Clinical Medicine, Shandong, China

Abstract

Objectives: Liver T1 is a potential magnetic resonance imaging biomarker for liver diseases. This study aimed to determine the T1 relaxation time of the normal liver (PDFF<5%) in healthy Asian volunteers using modified look-locker inversion recovery (MOLLI) and B1 inhomogeneity-corrected variable flip angle (B1-corrected VFA). Methods: 60 healthy Asian volunteers without focal or diffuse liver disease underwent a liver scan at 3T magnetic resonance. Proton density fat fraction (PDFF) and liver stiffness measurements were applied for the quantification of liver fat and fibrosis. T1 mapping was performed with MOLLI and B1-corrected VFA sequences. Bland-Altman, linear regression, Student t-test, and one-way analysis of variance were used for statistical analysis. Results: The mean T1 relaxation times of the whole liver were 901 ± 34 ms by MOLLI, and 948 ± 29 ms by B1-corrected VFA in healthy volunteers. There was a strong correlation (r = 0.86, p < 0.0001) for liver T1 between two T1 mapping methods. There were significant differences between the right and left lobes in liver T1 relaxation times using both methods (p < 0.05). Gender and Asian ethnic disparities had no impact on liver T1 relaxation times. Conclusion: T1 relaxation times of the normal liver (PDFF<5%) in healthy volunteers were established by MOLLI and B1-corrected VFA T1 mapping methods at 3T. It may provide suitable and robust baseline values for the assessment of liver diseases. Advances in knowledge: Gender and Asian ethnic disparities do not impact liver T1 relaxation time measurements.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3