Abstract

Objective: Evaluation of μCT scans of bone implant complexes often shows a specific problem: if an implant material has a very similar radiopacity as the embedding medium (e.g. methacrylate resin), the implant is not visible in the μCT image. Segmentation is not possible, and especially osseointegration as one of the most important parameter for biocompatibility is not evaluable. Methods: To ensure μCT visualisation and contrast enhancement of the evaluated materials, the embedding medium Technovit® VLC7200 was doped with an iodine monomer for higher radiopacity in different concentrations and tested regarding to handling, polymerisation, and histological preparation, and visualisation in µCT. Six different µCT devices were used and compared with regard to scan conditions, contrast, artefacts, image noise, and spatial resolution for the evaluation of the bone-implant blocks. Results: Visualisation and evaluation of all target structures showed very good results in all μCT scans as well as in histology and histological staining, without negative effects caused by iodine doping. Subsequent evaluation of explants of in vivo experiments without losing important information was possible with iodine doped embedding medium. Conclusion: Visualisation of implants with a similar radiopacity as the embedding medium could be considerably improved. µCT scan settings should be selected with the highest possible resolution, and different implant materials should be scanned individually for optimal segmentation. µCT devices with higher resolutions should be preferred. Advances in knowledge: Iodine doped embedding medium is a useful option to increase radiopacity for better visualisation and evaluation of special target structures in µCT.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3