One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results

Author:

Li Xiaotian1,Xia Fangjie2,Chen Lihua3,Zhang Xiaodong3,Mo Chunbai4,Shen Wen3

Affiliation:

1. School of Medicine, Nankai University, Tianjin, China

2. Department of Radiology, Tianjin First Center Hospital, Tianjin Medical University, Tianjin, China

3. Department of Radiology, Tianjin First Center Hospital, School of Medicine, Nankai University, Tianjin, China

4. Department of Kidney Transplantation, Tianjin First Center Hospital, School of Medicine, Nankai University, Tianjin, China

Abstract

Objective: The study was to investigate the feasibility and accuracy of assessment for living renal donors before transplantation by using 3.0 T non-contrast-enhanced magnetic resonance angiography (NCE-MRA). Methods: 30 renal donors were investigated and underwent computed tomography angiography (CTA) and 3.0 T NCE-MRA before nephrectomy. Two radiologists independently assessed arterial and venous anatomy and potential kidney lesions. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diameters and lengths of renal arteries and veins were compared between CTA and NCE-MRA. Imaging findings were compared with the surgical results served as reference standard. Agreement was assessed using κ test. The Wilcoxon test and paired sample t test were used for statistically significant differences. Results: The results of image quality score for renal arteries and veins were highly consistent between the two radiologists in NCE-MRA (p < 0.001). There was no significant difference in the scores of renal arterial and venous branches between NCE-MRA and CTA (p > 0.05). The SNR and CNR of renal vessels were higher than CTA (p < 0.001). There were no statistically significant differences in the length of renal vessels measured by the two methods (p > 0.05), and the diameter was smaller than that of CTA (p < 0.05). The detection of normal renal arteries and early branches by both examination techniques was consistent with intraoperative findings. Both methods showed good consistency between the anatomical variation of renal vein and the intraoperative diagnosis (p < 0.001). Conclusion: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for pre-operative vascular evaluation of living donor kidney transplantation. Advances in knowledge: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for pre-operative vascular evaluation of living donor kidney transplantation.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3