Clinical utility of postprocessed low-dose radiographs in skeletal imaging

Author:

Kolck Johannes1ORCID,Ziegeler Katharina1,Walter-Rittel Thula1,Hermann Kay Geert A.1,Hamm Bernd1,Beck Alexander1

Affiliation:

1. Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany

Abstract

Objectives: Radiography remains the mainstay of diagnostic and follow-up imaging. In view of the risks and the increasing use of ionizing radiation, dose reduction is a key issue for research and development. The introduction of digital radiography and the associated access to image postprocessing have opened up new opportunities to minimize the radiation dosage. These advances are contingent upon quality controls to ensure adequate image detail and maintenance of diagnostic confidence. The purpose of this study was to investigate the clinical applicability of postprocessed low-dose images in skeletal radiography. Methods: In our study setting, the median radiation dose for full dose X-rays was 9.61 dGy*cm2 for pelvis, 1.20 dGy*cm2 for shoulder and 18.64 dGy*cm2 for lumbar spine exams. Based on these values, we obtained 200 radiographs for each anatomic region in four consecutive steps, gradually reducing the dose to 84%, 71%, 60% and 50% of the baseline using an automatic exposure control (AEC). 549 patients were enrolled for a total of 600 images. All X-rays were postprocessed with a spatial noise reduction algorithm. Two radiologists assessed the diagnostic value of the radiographs by rating the visualization of anatomical landmarks and image elements on a five-point Likert scale. A mean-sum score was calculated by averaging the two reader’s total scores. Given the non-parametric distribution, we used the Mann-Whitney U test to evaluate the scores. Results: Median dosage at full dose accounted for 38.4%, 48 and 53.2% of the German reference dose area product for shoulder, pelvis and lumbar spine, respectively. The applied radiation was incrementally reduced to 21.5%, 18.4% and 18.7% of the respective reference value for shoulder, pelvis and lumbar spine. Throughout the study, we observed an estimable tendency of superior quality at higher dosage in overall image quality. Statistically significant differences in image quality were restricted to the 50% dose groups in shoulder and lumbar spine images. Regardless of the applied dosage, 598 out of 600 images were of sufficient diagnostic value. Conclusion: In digital radiography image postprocessing allows for extensive reduction of radiation dosage. Despite a trend of superior image detail at higher dose levels, overall quality and, more importantly, diagnostic utility of low-dose images was not significantly affected. Therefore, our results not only confirm the clinical utility of postprocessed low-dose radiographs, but also suggest a widespread deployment of this advanced technology to ensure further dose limitations in clinical practice. Advances in knowledge: The diagnostic image quality of postprocessed skeletal radiographs is not significantly impaired even after extensive dose reduction by up to 20% of the reference value.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3