The use of digital magnification to reduce radiation dose in the cardiac catheter laboratory

Author:

Dalvi Shailesh1,Roberts Hywel Mortimer1,Bellamy Christopher1,Rees Michael12ORCID

Affiliation:

1. North Wales Cardiac Centre, Rhyl, UK

2. Bangor University, Bangor, UK

Abstract

Objectives: To audit whether using magnification of images by use of a large viewing screen using digital matrix magnification which enlarges the image by 33% without using the X-ray machine zoom magnification protocols on a Siemens Artis Zee X-ray machine in a cardiac catheter laboratory results in a reduction of kerma–area product (KAP) for both diagnostic and interventional procedures. This reduction was predicted in an in vitro study in our laboratory, which has previously shown a 20.4% reduction in KAP. Methods: A retrospective analysis was conducted of the radiation exposure to compare the measured KAP recorded during the period when conventional magnification with automatic brightness and dose control was used on a Siemens Artis Zee X-ray machine with a flat panel detector and when magnification settings were avoided by using a large screen to enlarge and project a non-magnified image by digital magnification. The analysis was carried out for patients having a diagnostic coronary angiogram and those having an interventional coronary procedure. Results: For diagnostic coronary angiograms the median KAP per procedure in the period using conventional magnification was 2124.5 µGy.m2 compared to 1401 µGy.m2 when image matrix magnification was used, a 34% reduction (p < 0.0001). For interventional coronary procedures, the median KAP per procedure in the period using conventional magnification was 3791 µGy.m2 compared to 2568.5 µGy.m2 when image matrix magnification was used, a 32% reduction (p < 0.0001). Conclusion: Avoiding using conventional magnification in the cardiac catheter laboratory and using a large screen to magnify images was associated with a statistically significant greater than 30% reduction in KAP. Advances in knowledge: This paper is the proof in clinical practice of a theoretical conclusion that radiation dose (KAP) is reduced by use of Image matrix magnification using a large viewing screen without the need to use X-ray tube magnification without significant loss of image resolution in interventional cardiology. The same approach will be useful in interventional radiology.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3