Two birds with one stone: can [68Ga]Ga-DOTANOC PET/CT image quality be improved through BMI-adjusted injected activity without increasing acquisition times?

Author:

Zanoni Lucia1,Calabrò Diletta2,Fortunati Emilia2,Argalia Giulia2,Malizia Claudio1,Allegri Vincenzo1,Civollani Simona1,Fanti Stefano12,Ambrosini Valentina12

Affiliation:

1. Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy

2. Department of Experimental Diagnostic and Specialized Medicine (DIMES), Alma Mater Studiorum University of Bologna, Bologna, Italy

Abstract

Objectives: To assess how patients’ dependent parameters may affect [68Ga]Ga-DOTANOC image quality and to propose a theoretical body mass index (BMI)-adjusted injected activity (IA) scheme, to improve imaging of high weight patients. Methods: Among patients prospectively enrolled (June-2019 and May-2020) in an Institutional Ethical Committee-approved electronic archive, we included those affected by primary gastro-entero-pancreatic (GEP) or lung neuroendocrine tumour and referred by our Institutional clinicians (excluding even minimal radiopharmaceutical extravasation, movement artefacts, renal insufficiency). All PET/CT images were acquired following EANM guidelines and rated for visual quality (1 = non-diagnostic, 2 = poor, 3 = moderate, 4 = good). Collected data included patient’s body mass, height, BMI, age, IA (injected activity), IA/Kg (IAkg), IA/BMI (IABMI), liver SUVmean, liver SUVmax standard deviation, liver-signal-to-noise (LSNR), normalised_LSNR (LSNR_norm) and contrast-to-noise ratio (CNR) for positive scans and were compared to image rating (poor vs moderate/good). Results: Overall, 77 patients were included. Rating concordance was high (agreement = 81.8%, Fleiss k score = 0.806). All patients’ dependent parameters resulted significantly different between poor-rated and moderate/good-rated scans (IA: p = 0.006, IAkg: p =< 0.001, body weight: p =< 0.001, BMI: p =< 0.001, IABMI: p =< 0.001). Factors significantly associated with moderate/good rating were BMI (p =< 0.001), body weight (p =< 0.001), IABMI (p =< 0.001), IAkg (p = 0.001), IA (p = 0.003), LSNR_norm (p = 0.01). The BMI-based model presented the best predictive efficiency (81.82%). IABMI performance to differentiate moderate/good from poor rating resulted statistically significant (IA-AUC = 0.78; 95% CI: 0.68–0.89; cut-off value of 4.17 MBq*m2/kg, sensitivity = 81.1%, specificity = 66.7%). If BMI-adjusted IA (=4.17*BMI) would have been applied in this population, the median IA would have slightly inferior (−4.8%), despite a different IA in each patient. Advances in knowledge: BMI resulted the best predictor of image quality. The proposed theoretical BMI-adjusted IA scheme (4.17*BMI) should yield images of better quality (especially in high-BMI patients) maintaining practical scanning times (3 min/bed).

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3