Patient doses in endovascular and hybrid revascularization of aortoiliac segment

Author:

Stanev Stefan1,Kostova-Lefterova Desislava234,Dineva Svetla245

Affiliation:

1. St. George University Hospital, Plovdiv, Bulgaria

2. National Cardiology Hospital, Sofia, Bulgaria

3. Medical University – Pleven, Pleven, Bulgaria

4. Aleksandrovska University Hospital, Sofia, Bulgaria

5. Medical University – Sofia, Sofia, Bulgaria

Abstract

Objectives: Constantly increasing number of procedures performed – endovascular or hybrid in patients with aortoiliac occlusive disease during the last decades finds its explanation in the lower morbidity and mortality rates, compared to bypass surgery. The purpose of the current survey was to estimate patients’ radiation exposure in aortoiliac segment after endovascular or hybrid revascularization and to study the main factors which have direct contribution. Methods: A retrospective study of 285 procedures conducted with the help of a mobile C-arm system in 223 patients was performed. Procedures were grouped according to criteria such as: type of intervention, vascular access, level of complexity and operating team. Different analyses were performed within the groups and dose values. Results: The median values of kerma–air product (KAP), the number of series and the peak skin dose (PSD) significantly increase with the increasing number of vascular accesses: for one access (16.68 Gy.cm2, 6 and 336 mGy), for two (56.93 Gy.cm2, 11 and 545 mGy), and for three (102.28 Gy.cm2, 15 and 781 mGy). Significant dependence was observed in the case of single access site between the type of access and the dose values: hybrid and retrograde common femoral artery/superficial femoral artery (CFA/SFA) endovascular accesses, 10.06 Gy.cm2/301 mGy and 13.23 Gy.cm2/318 mGy respectively, in contrast with the contralateral CFA and left brachial access, 33 Gy.cm2/421 mGy and 38.33 Gy.cm2/448 mGy respectively. Conclusion: The results demonstrate that the most important factors increasing the dose values are number and type of vascular accesses, followed by the combination and number of implanted stents with the complexity of the procedure. The PSD values for a single procedure were between 2 and 12 times lower than those IAEA proposed as trigger levels for radiation-induced erythema. This study shows that trigger levels were not reached even for patients with repeated procedures in the same segment in 1-year period. Advances in knowledge: The study gives important understanding and clarity on the growing awareness for dose-modifying factors during endovascular and hybrid revascularization of aortoiliac segment.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3