Optimized scan delay for late hepatic arterial or pancreatic parenchymal phase in dynamic contrast-enhanced computed tomography with bolus-tracking method

Author:

Noda Yoshifumi1,Kawai Nobuyuki1,Ishihara Takuma2,Tsuboi Yoshiki2,Kaga Tetsuro1,Miyoshi Toshiharu3,Hyodo Fuminori4,Matsuo Masayuki1

Affiliation:

1. Department of Radiology, Gifu University, Gifu, Japan

2. Innovative and Clinical Research Promotion Center, Gifu University Hospital, Gifu, Japan

3. Department of Radiology Services, Gifu University Hospital, Gifu, Japan

4. Department of Radiology, Frontier Science for Imaging, Gifu University, Gifu, Japan

Abstract

Objectives: To determine the optimal scan delay corresponding to individual hemodynamic status for pancreatic parenchymal phase in dynamic contrast-enhanced CT of the abdomen. Methods: One hundred and fourteen patients were included in this retrospective study (69 males and 45 females; mean age, 67.9 ± 12.1 years; range, 39–87 years). These patients underwent abdominal dynamic contrast-enhanced CT between November 2019 and May 2020. We calculated and recorded the time from contrast material injection to the bolus-tracking trigger of 100 Hounsfield unit (HU) at the abdominal aorta (s) (TimeTRIG) and scan delay from the bolus-tracking trigger to the initiation of pancreatic parenchymal phase scanning (s) (TimeSD). The scan delay ratio (SDR) was defined by dividing the TimeSD by TimeTRIG. Non-linear regression analysis was conducted to assess the association between CT number of the pancreas and SDR and to reveal the optimal SDR, which was ≥120 HU in pancreatic parenchyma. Results: The non-linear regression analysis showed a significant association between CT number of the pancreas and the SDR (p < 0.001). The mean TimeTRIG and TimeSD were 16.1 s and 16.8 s, respectively. The SDR to peak enhancement of the pancreas (123.5 HU) was 1.00. An SDR between 0.89 and 1.18 shows an appropriate enhancement of the pancreas (≥120 HU). Conclusion: The CT number of the pancreas peaked at an SDR of 1.00, which means TimeSD should be approximately the same as TimeTRIG to obtain appropriate pancreatic parenchymal phase images in dynamic contrast-enhanced CT with bolus-tracking method. Advances in knowledge: The hemodynamic state is different in each patient; therefore, scan delay from the bolus-tracking trigger should also vary based on the time from contrast material injection to the bolus-tracking trigger. This is necessary to obtain appropriate late hepatic arterial or pancreatic parenchymal phase images in dynamic contrast-enhanced CT of the abdomen.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3