Artificial intelligence can detect left ventricular dilatation on contrast-enhanced thoracic computer tomography relative to cardiac magnetic resonance imaging

Author:

Asif Ashar1,Charters Pia F. P.2,Thompson Charlotte A. S.2,Komber Hend M. E. I.2,Hudson Benjamin J.2,Rodrigues Jonathan Carl Luis23ORCID

Affiliation:

1. Medical School, University of Bristol, Bristol, UK

2. Department of Radiology, Royal United Hospital, Bath, UK

3. Department of Health, University of Bath, Bath, UK

Abstract

Objectives: To assess the diagnostic accuracy of an automated algorithm to detect left ventricular (LV) dilatation on non-ECG gated CT, using cardiac magnetic resonance (CMR) as reference standard. Methods Consecutive patients with contrast-enhanced CT thorax and CMR within 31 days (2016–2020) were analysed (n = 84). LV dilatation was defined against age-, sex- and body surface area-specific values for CMR. CTs underwent automated artificial intelligence(AI)-derived analysis that segmented ventricular chambers, presenting maximal LV diameter and volume. Area under the receiver operator curve (AUC-ROC) analysis identified CT thresholds with ≥90% sensitivity and highest specificity and ≥90% specificity with highest sensitivity. Youden’s Index was used to identify thresholds with optimised sensitivity and specificity. Results: Automated diameter analysis was feasible in 92% of cases (77/84; 45 men, age 61 ± 14 years, mean CT to CMR interval 10 ± 8 days). Relative to CMR as a reference standard, 45% had LV dilatation. In males, an automated LV diameter measurement of ≥55.5 mm was ≥90% specific for CMR-defined LV dilatation (positive predictive value (PPV) 85.7%, negative predictive value (NPV) 61.2%, accuracy 68.9%). In females, an LV diameter of ≥49.7 mm was ≥90% specific for CMR-defined LV dilatation (PPV 66.7%, NPV 73.1%, accuracy 71.9%). AI CT volumetry data did not significantly improve AUC performance. Conclusion: Fully automated AI-derived analysis LV dilatation on routine unselected non-gated contrast-enhanced CT thorax studies is feasible. We have defined thresholds for the detection of LV dilatation on CT relative to CMR, which could be used to routinely screen for dilated cardiomyopathy at the time of CT. Advances in knowledge: We show, for the first time, that a fully-automated AI-derived analysis of maximal LV chamber axial diameter on non-ECG-gated thoracic CT is feasible in unselected real-world cases and that the derived measures can predict LV dilatation relative to cardiac magnetic resonance imaging, the non-invasive reference standard for determining cardiac chamber size. We have derived sex-specific cut-off values to screen for LV dilatation on routine contrast-enhanced thoracic CT. Future work should validate these thresholds and determine if technology can alter clinical outcomes in a cost-effective manner.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3