Radiopaque drug-eluting embolisation beads as fiducial markers for stereotactic liver radiotherapy

Author:

Beaton Laura1,Daly Mairead2,Tregidgo Henry FJ3,Grimes Helen2,Moinuddin Syed2,Stacey Chris2,Znati Sami1,Hague Julian2,Bascal Zainab A4,Wilde Paul E4,Cooper Sarah4,Bandula Steven2,Lewis Andrew L4,Clarkson Matthew J2,Sharma Ricky A15

Affiliation:

1. University College London Cancer Institute, University College London, London, United Kingdom

2. University College London Hospitals NHS Foundation Trust, London, United Kingdom

3. Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom

4. Biocompatibles UK Ltd, Lakeview, Riverside Way, Watchmoor Park, Camberley, Surrey, United Kingdom

5. National Institute for Health Research University College London Hospitals Biomedical Centre, University College London Cancer Institute, London, United Kingdom

Abstract

Objective: To determine the feasibility of using radiopaque (RO) beads as direct tumour surrogates for image-guided radiotherapy (IGRT) in patients with liver tumours after transarterial chemoembolisation (TACE). Methods: A novel vandetanib-eluting RO bead was delivered via TACE as part of a first-in-human clinical trial in patients with either hepatocellular carcinoma or liver metastases from colorectal cancer. Following TACE, patients underwent simulated radiotherapy imaging with four-dimensional computed tomography (4D-CT) and cone-beam CT (CBCT) imaging. RO beads were contoured using automated thresholding, and feasibility of matching between the simulated radiotherapy planning dataset (AVE-IP image from 4D data) and CBCT scans assessed. Additional kV, MV, helical CT and CBCT images of RO beads were obtained using an in-house phantom. Stability of RO bead position was assessed by comparing 4D-CT imaging to CT scans taken 6–20 days following TACE. Results: Eight patients were treated and 4D-CT and CBCT images acquired. RO beads were visible on 4D-CT and CBCT images in all cases and matching successfully performed. Differences in centre of mass of RO beads between CBCT and simulated radiotherapy planning scans (AVE-IP dataset) were 2.0 mm mediolaterally, 1.7 mm anteroposteriorally and 3.5 mm craniocaudally. RO beads in the phantom were visible on all imaging modalities assessed. RO bead position remained stable up to 29 days post TACE. Conclusion: RO beads are visible on IGRT imaging modalities, showing minimal artefact. They can be used for on-set matching with CBCT and remain stable over time. Advances in knowledge: The role of RO beads as fiducial markers for stereotactic liver radiotherapy is feasible and warrants further exploration as a combination therapy approach.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3