National Diagnostic Reference Level (DRL) for nuclear medicine computed tomography–positron emission tomography hybrid imaging studies for kuwait population: second phase dose audit-2019

Author:

Masoomi Michael1ORCID,Al-Shammeri Iman1,Al-Kandari Latifah2,Elrahman Hany1,Al-Shammeri Jehan3

Affiliation:

1. Nuclear Medicine and Molecular Imaging Section, Department of Medical Imaging, Adan Hospital, MOH, Hadiya, Kuwait

2. Radiology Section, Department of Medical Imaging, Adan Hospital, MOH, Hadiya, Kuwait

3. Nuclear Medicine Department, Faculty of Medicine, Kuwait University, Kuwait City, Kuwait

Abstract

Objective: Diagnostic reference levels (DRLs) for CT part of positron emission tomography-CT (PET-CT) examinations are limited. The study was aiming to execute the second phase of the national DRL in support of optimisation and dose reduction in State of KW. Methods: In this multicentre collaborative PET-CT study, oncology patient data were exclusively collected due to the National MOH Ethical Committee recommendation and limitation of the other studies. Median, Mean, SD, 75th, 25th percentiles as well as whole body (WB) effective dose (ED) were calculated. The study was UK-IPEM-based methodology and it was the second phase of the study in Kuwait. Results: Half body (HB) and WB scans were 65 and 35% of the total enterers (309). The third quartile dose–length product (DLP) (mGy x cm) and volumetric CT dose index (mGy) values for the HB (537, 5) were higher than the UK NDRL (400, 4.3) but were lower than the Swiss NDRL (620, 6) and the France NDRL (762, 7.7). Comparatively, the proposed NDRLs for the WB (684, 4.1) were lower than Swiss National Data (720, 5.0) though, the Swiss had about 5000 (HB) & 706 (WB), the UK had 370 (HB) and France had 1000 (HB) entries. Calculated ED varied from 4.1 to 10.2 mSv, (mean values = 6.9 mSv) for HB and from 2.6 to 7 mSv (mean value = 4.6 mSv). Conclusions: There was 9.1% improvement in NDRL for 2019, compared to 2018, but there is a continuous need for improving NDRL. Advances in knowledge: Data provided a trend of NDRL that is served as a national data bank for continuous optimisation.

Publisher

British Institute of Radiology

Subject

Materials Chemistry,Economics and Econometrics,Media Technology,Forestry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3