Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing

Author:

Shirata Ryosuke12,Inoue Tatsuya3,Sugimoto Satoru3,Saito Anneyuko I3,Omura Motoko2,Minagawa Yumiko2,Sasai Keisuke3

Affiliation:

1. Department of Radiation Oncology, Graduate School of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, Japan

2. Department of Radiation Oncology, Shonan Kamakura General Hospital, 1370-1 Okamoto, Kamakura, Kanagawa, Japan

3. Department of Radiation Oncology, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, Japan

Abstract

Objective: Intensity-modulated radiotherapy (IMRT) is a well-established radiotherapy technique for delivering radiation to cancer with high conformity while sparing the surrounding normal tissue. Two main purposes of this study are: (1) to investigate dose calculation accuracy of helical IMRT (HIMRT) and volumetric-modulated arc therapy (VMAT) on surface region and (2) to evaluate the dosimetric efficacy of HIMRT and VMAT for scalp-sparing in whole brain radiotherapy (WBRT). Methods: First, using a radiochromic film and water-equivalent phantom with three types of boluses (1, 3, 5 mm), calculation/measurement dose agreement at the surface region in the VMAT and HIMRT plans were examined. Then, HIMRT, 6MV-VMAT and 10MV-VMAT with scalp-sparing, and two conventional three-dimensional conformal radiotherapy plans (6MV-3DCRT and 10MV-3DCRT; as reference data) were created for 30 patients with brain metastasis (30 Gy/10 fractions). The mean dose to the scalp and the scalp volume receiving 24 and 30 Gy were compared. Results: The percentage dose differences between the calculation and measurement were within 7%, except for the HIMRT plan at a depth of 1 mm. The averaged mean scalp doses [Gy], V24Gy [%], and V30Gy [%] (1SD) for 6MV-3DCRT, 10MV-3DCRT, HIMRT, 6MV-VMAT, and 10MV-VMAT were [26.6 (1.1), 86.4 (7.3), 13.2 (4.2)], [25.4 (1.0), 77.8 (7.5), 13.2 (4.2)], [23.2 (1.5), 42.8 (19.2), 0.2 (0.5)], [23.6 (1.6), 47.5 (17.9), 1.2 (1.8)], and [22.7 (1.7), 36.4 (17.6), 0.7 (1.1)], respectively. Conclusion: Regarding the dose parameters, HIMRT achieved a lower scalp dose compared with 6MV-VMAT. However, the highest ability to reduce the mean scalp dose was showed in 10MV-VMAT. Advances in knowledge: Scalp-sparing WBRT using HIMRT or VMAT may prevent radiation-induced alopecia in patients with BM.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3