Repeatability and reproducibility of MRI apparent diffusion coefficient applied on four different regions of interest for patients with axial spondyloarthritis and healthy volunteers scanned twice within a week

Author:

Møller Jakob Møllenbach12ORCID,Østergaard Mikkel23,Thomsen Henrik S12,Hangaard Stine1,Sørensen Inge J23,Madsen Ole Rintek23,Pedersen Susanne J3

Affiliation:

1. Department of Radiology, Herlev-Gentofte Hospital, Herlev, Denmark

2. Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark

3. Copenhagen Center for Arthritis Research, Center for Rheumatology and Spine Diseases, Rigshospitalet, Glostrup, Denmark

Abstract

Objectives: The apparent diffusion coefficient (ADC) may be used as a biomarker for diagnosis and/or monitoring treatment response in patients with axial spondyloarthritis (axSpA), but this requires reliable ADC measurements. This study assessed test–retest repeatability and reproducibility of ADC measurements using four different region of interest (ROI) settings. Methods: In this prospective study, the sacroiliac joints (SIJs) of 25 patients with axSpA and 24 age- and sex-matched healthy volunteers were imaged twice at a mean interval of 6.8 days in a 1.5 T scanner using, multishot echoplanar diffusion-weighted sequences. ADCs at four ROI settings were assessed: 5 mm and 10 mm anatomic band-shaped, 15 mm linear, and 40 mm2 circular. Results: Intraclass correlation coefficient (ICC) assessments showed that the interstudy repeatability was good for median ADC (ADCmed) and 95th-percentile ADC (ADC95) measurements in patients with axSpA (0.77–0.83 and 0.75–0.83, respectively), but poor-to-moderate in healthy subjects (0.27–0.55 and 0.13–0.37, respectively). For all ROI settings, intrareader reproducibility was excellent for ADCmed-measurements (ICC:0.85–0.99) and moderate-to-excellent for ADC95 measurements (ICC:0.68–0.96). The 5 mm ROI had the least estimated bias and highest level of agreement on Bland–Altman plots. The interreader reproducibility was moderate (ICC:0.71). The 15 mm linear ROI produced significantly greater ADCmed and ADC95 measurements than all other ROI settings (p < 0.01–0.02), except for the circular ROI ADC95 measurements. Conclusion: ROI settings influence ADC measurements. Interstudy repeatability of SIJ ADC measurements is independent of ROI settings. However, the 5 mm ROI showed the least bias and random error and seems preferable. Advances in knowledge: ADC measurements are affected by ROI settings, and this should be taken into account when assessing ADC maps.

Publisher

British Institute of Radiology

Subject

Materials Chemistry,Economics and Econometrics,Media Technology,Forestry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3