Diagnostic accuracy of non-contrast abdominopelvic computed tomography scans in follow-up of breast cancer patients

Author:

Nam Sang Yu1,Ahn Su Joa1,Jang Young Rock2,Chun Yong Soon3,Park Heung Kyu3,Choi Seung Joon1,Choi Hye Young1,Kim Jeong Ho1

Affiliation:

1. Department of Radiology, Gil Medical Center of Gachon University, Incheon, South Korea

2. Department of Internal Medicine, Gil Medical Center of Gachon University, Incheon, South Korea

3. Department of Surgery Breast Cancer Center, Gil Medical Center of Gachon University, Incheon, South Korea

Abstract

Objectives: To evaluate the effectiveness of follow-up with non-enhanced CT (NECT) in patients with breast cancer. Methods: The present retrospective study included 1396 patients with breast cancer. Group A included patients with no metastasis to evaluate the diagnostic performance of NECT in detecting newly developed metastasis. Group B included patients with known hepatic metastasis to evaluate the accuracy of NECT for the assessment of hepatic metastasis. Results: Group A included 895 patients (mean age 52.8 years). Among them, 145 patients had 160 metastases. The per-patient sensitivities for diagnosing newly developed metastasis were 68.3 and 53.8% according to the two reviewers, while the per-lesion sensitivities were 89.4 and 85.0%. Sensitivities for bone metastasis were 98.9 and 95.9%, while sensitivities for hepatic metastasis were 73.7 and 68.4%. In group B, the accuracy of hepatic metastasis response evaluation according to the RECIST criteria was 70.8% for reviewer 1 and 63.8% for reviewer 2. Conclusions: NECT showed inadequate diagnostic performance in detecting newly developed metastasis and in evaluating the response of hepatic metastasis. However, NECT can be utilized as a follow-up modality in patients with decreased renal function or hypersensitivity to iodinated contrast media. Advances in knowledge: The risk of side effects of contrast media should be considered as important when NECT can be utilized as a follow-up modality in decreased renal function patients.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Allergy to Radiocontrast Dye;Immunology and Allergy Clinics of North America;2022-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司