Dependence of radiomic features on pixel size affects the diagnostic performance of radiomic signature for the invasiveness of pulmonary ground-glass nodule

Author:

Tao Guangyu1,Yin Lekang2,Shi Dejun3,Ye Jianding1,Lu Zhenghai4,Zhou Zhen3,Yu Yizhou3,Ye Xiaodan1,Yu Hong1

Affiliation:

1. Department of Radiology, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai, China

2. Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China

3. Deepwise AI Lab, Beijing, China

4. Department of Radiology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

Abstract

Objective: To investigate the effect of reducing pixel size on the consistency of radiomic features and the diagnostic performance of the downstream radiomic signatures for the invasiveness for pulmonary ground-glass nodules (GGNs) on CTs. Methods: We retrospectively collected the clinical data of 182 patients with GGNs on high resolution CT (HRCT). The CT images of different pixel sizes (0.8mm, 0.4mm, 0.18 mm) were obtained by reconstructing the single HRCT scan using three combinations of field of view and matrix size. For each pixel size setting, radiomic features were extracted for all GGNs and radiomic signatures for the invasiveness of GGNs were built through two modeling pipelines for comparison. Results: The study finally extracted 788 radiomic features. 87% radiomic features demonstrated inter pixel size variation. By either modeling pipeline, the radiomic signature under small pixel size performed significantly better than those under middle or large pixel sizes in predicting the invasiveness of GGNs (p’s value <0.05 by Delong test). With the independent modeling pipeline, the three pixel size bounded radiomic signatures shared almost no common features. Conclusions: Reducing pixel size could cause inconsistency in most radiomic features and improve the diagnostic performance of the downstream radiomic signatures. Particularly, super HRCTs with small pixel size resulted in more accurate radiomic signatures for the invasiveness of GGNs. Advances in knowledge: The dependence of radiomic features on pixel size will affect the performance of the downstream radiomic signatures. The future radiomic studies should consider this effect of pixel size.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3