Effects of artery input function on dynamic contrast-enhanced MRI for determining grades of gliomas

Author:

Jia Lin1,Wu Xia23,Wan Qian345,Wan Liwen345,Jia Wenxiao1,Zhang Na345ORCID

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Xin Jiang Medical University, Urumqi, China

2. School of Information Engineering, Wuhan University of Technology, Wuhan, China

3. Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

4. CAS Key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

5. Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

Abstract

Objective: To evaluate the effect of artery input function (AIF) derived from different arteries for pharmacokinetic modeling on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters in the grading of gliomas. Methods: 49 patients with pathologically confirmed gliomas were recruited and underwent DCE-MRI. A modified Tofts model with different AIFs derived from anterior cerebral artery (ACA), ipsilateral and contralateral middle cerebral artery (MCA) and posterior cerebral artery (PCA) was used to estimate quantitative parameters such as Ktrans (volume transfer constant) and Ve (fractional extracellular-extravascular space volume) for distinguishing the low grade glioma from high grade glioma. The Ktrans and Ve were compared between different arteries using Two Related Samples Tests (TRST) (i.e. Wilcoxon Signed Ranks Test). In addition, these parameters were compared between the low and high grades as well as between the grade II and III using the Mann-Whitney U-test. A p-value of less than 0.05 was regarded as statistically significant. Results: All the patients completed the DCE-MRI successfully. Sharp wash-in and wash-out phases were observed in all AIFs derived from the different arteries. The quantitative parameters (Ktrans and Ve) calculated from PCA were significant higher than those from ACA and MCA for low and high grades, respectively (p < 0.05). Despite the differences of quantitative parameters derived from ACA, MCA and PCA, the Ktrans and Ve from any AIFs could distinguish between low and high grade, however, only Ktrans from any AIFs could distinguish grades II and III. There was no significant correlation between parameters and the distance from the artery, which the AIF was extracted, to the tumor. Conclusion: Both quantitative parameters Ktrans and Ve calculated using any AIF of ACA, MCA, and PCA can be used for distinguishing the low- from high-grade gliomas, however, only Ktrans can distinguish grades II and III. Advances in knowledge: We sought to assess the effect of AIF on DCE-MRI for determining grades of gliomas. Both quantitative parameters Ktrans and Ve calculated using any AIF of ACA, MCA, and PCA can be used for distinguishing the low- from high-grade gliomas.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3