Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma

Author:

Gumeler Ekim1ORCID,Parlak Safak1,Yazici Gozde2,Karabulut Erdem3,Kiratli Hayyam4,Oguz Kader K1

Affiliation:

1. Department of Radiology, Hacettepe University, School of Medicine, Ankara, Turkey

2. Department of Radiation Oncology, Hacettepe University, School of Medicine, Ankara, Turkey

3. Department of Biostatistics, Hacettepe University, School of Medicine, Ankara, Turkey

4. Department of Ophtalmology, Hacettepe University, School of Medicine, Ankara, Turkey

Abstract

Objectives: Diffusion weighted imaging (DWI) has become important for orbital imaging. However, the echoplanar imaging (EPI) DWI has inherent obstacles due to susceptibility to magnetic field inhomogeneities. We conducted a comparative study assessing the image quality of orbits in a patient cohort with uveal melanoma (UM). We hypothesized that single shot turbo spin echo (ssTSE) DWI would have better image quality in terms of less distortion and artifacts and yield better tissue evaluation compared to ssEPI-DWI. Methods: ssEPI-DWI and ssTSE-DWI of orbits were obtained from 50 patients with uveal melanoma who were prospectively enrolled in the study. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diffusion signal properties, and apparent diffusion coefficient (ADC) values were collected and compared between ssEPI-DWI and ssTSE-DWI. Two reviewers evaluated and compared the geometric distortion, susceptibility and ghosting artifacts, resolution, demarcation of ocular mass, and overall quality. Results: A higher DR was found in ssEPI-DWI compared to ssTSE-DWI (p < 0.001). SNR and CNR were lower for the temporal lobe cortex (p ≤ 0.004), but higher for melanoma in ssEPI-DWI than ssTSE-DWI (p ≤ 0.037). Geometric distortion and artifacts were more common in ssEPI-DWI (p < 0.001). Resolution (p ≤ 0.013) and overall quality (p < 0.001) were better in ssTSE-DWI. Ocular masses were demarcated better on ssEPI-DWI (p ≤ 0.002). Significant negative correlations between T1 and T2 signal intensities (r = −0.369, p ≤ 0.008) and positive correlations between T2 and both DWI signal intensities (r = 0.686 and p < 0.001 for ssEPI-DWI, r = 0.747 and p < 0.001 for ssTSE-DWI) were revealed. Conclusion: With less geometric distortion and susceptibility artifacts, better resolution, and overall quality, ssTSE-DWI can serve as an alternative to ssEPI-DWI for orbital DWI. Advances in knowledge: ssTSE-DWI can be a better alternative of diffusion imaging of orbits with less susceptibility artifact and geometric distortion compared to ssEPI-DWI.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3