Abstract

Objectives: Leeds Test Object Ten (TO.10) is routinely used to subjectively estimate Threshold Contrast Detail Detectability (TCDD) as a measure of image quality in fluoroscopy. However, manufacturer guidance provides calibrated contrasts for only limited peak voltage and copper filtration thickness combinations. Prescribed testing conditions are often difficult to attain as modern flat panel fluoroscopic systems independently determine voltage and copper filtration thickness settings. This work aims to extend the range of TO.10 contrasts available for routine testing at peak voltage and copper thickness settings likely to be encountered. Methods: Two methods are described for generalising the calculation of target contrasts: a three-dimensional interpolation/extrapolation model in MATLAB®, and a multivariate log-polynomial function. Both methods utilise the available calibrated contrasts to estimate contrasts at voltage and copper thickness combinations routinely encountered. Results: Results are presented as Threshold Detection Index [Formula: see text] curves fit by a second-order polynomial of log [Formula: see text] to log [Formula: see text] . Results are found to be more accurate at unprescribed conditions while also reproducible for relatively consistent input air kerma rate (IAKR) expected from automatic dose rate controls (ADRC). Conclusions: The calculation of TO.10 contrasts at non-standard conditions aids in the determination of an absolute estimate of image quality in fluoroscopy with greater accuracy, reproducibility and efficiency. Advances in knowledge: TO.10 detail contrasts for TCDD testing of fluoroscopy units have been significantly extended beyond those previously available. The described methods will aid the clinical physicist in absolute assessments of fluoroscopic image quality and facilitate inter system comparisons.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3