Usefulness of two-point Dixon T2-weighted imaging in thyroid-associated ophthalmopathy: comparison with conventional fat saturation imaging in fat suppression quality and staging performance

Author:

Chen Lu1,Hu Hao1,Chen Huan-Huan2,Chen Wen1,Wu Qian1,Wu Fei-Yun1,Xu Xiao-Quan1

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China

2. Department of Endocrinology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China

Abstract

Objective:To compare the two-point Dixon T2weighted imaging (T2WI) with conventional fat-sat T2WI in fat suppression (FS) quality and staging performance for patients with TAO.Methods:We enrolled 37 thyroid-associated ophthalmopathy (TAO) patients and 15 healthy controls who underwent both coronal two-point Dixon and fat-sat T2WI. Qualitative (overall imaging quality, FS uniformity) and quantitative [signal intensity ratio of extraocular muscle (EOM-SIR)] parameters were assessed between the two-point Dixon T2WI and fat-sat T2WI. Additionally, water fraction of intraorbital fat (IF-WF) was measured on Dixon image. Dixon-EOM-SIR, Fat-sat-EOM-SIR and Dixon-IF-WF values were compared between active and inactive TAO groups, and the diagnostic efficiency for the active phase were evaluated.Results:Two-point Dixon T2WI showed significantly higher overall image quality score, FS uniformity score as well as EOM-SIR value than fat-sat T2WI in both TAO and control groups (all p < 0.05). Active TAOs had significantly higher Dixon-EOM-SIR (p < 0.001), Fat-sat-EOM-SIR (p < 0.001) and Dixon-IF-WF (p = 0.001) than inactive TAOs. ROC curves analyses indicated that Dixon-EOM-SIR ≥3.32 alone demonstrated the highest staging sensitivity (75.0%). When integrating Dixon-EOM-SIR ≥3.32 and Dixon-IF-WF ≥0.09, improved staging efficiency and specificity could be achieved (area under the curve, 0.872; specificity, 97.1%).Conclusion:Compared with conventional fat-sat technique, two-point Dixon T2WI offers better image quality, as well as improved staging sensitivity and specificity for TAO. Dixon T2WI is suggested to be used to evaluate the patients with TAO in clinical practice.Advances in knowledge:Two-point Dixon T2WI offers better image quality than fat-sat T2WI. Dixon-EOM-SIR alone demonstrated the highest staging sensitivity. Combining with Dixon-IF-WF showed improved staging efficiency and specificity. Dixon T2WI is suggested to be used to evaluate TAO patients in clinical practice.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3