Real-time MRI of the moving wrist at 0.55 tesla

Author:

Chaudhari Abhijit J1ORCID,Lim Yongwan2,Cui Sophia X.3,Bayne Christopher O.4,Szabo Robert M.4,Boutin Robert D.5,Nayak Krishna S2

Affiliation:

1. Department of Radiology, University of California, Davis, Sacramento, CA, USA

2. Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA

3. Siemens Medical Solutions USA Inc., Malvern, PA, USA

4. Department of Orthopaedic Surgery, University of California Davis, Sacramento, CA, USA

5. Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA

Abstract

Objectives: Magnetic resonance imaging (MRI) using 1.5T or 3.0T systems is routinely employed for assessing wrist pathology; however, due to off-resonance artifacts and high power deposition, these high-field systems have drawbacks for real-time (RT) imaging of the moving wrist. Recently, high-performance 0.55T MRI systems have become available. In this proof-of-concept study, we tested the hypothesis that RT-MRI during continuous, active, and uninterrupted wrist motion is feasible with a high-performance 0.55T system at temporal resolutions below 100 ms and that the resulting images provide visualization of tissues commonly interrogated for assessing dynamic wrist instability. Methods: Participants were scanned during uninterrupted wrist radial-ulnar deviation and clenched fist maneuvers. Resulting images (nominal temporal resolution of 12.7–164.6 ms per image) were assessed for image quality. Feasibility of static MRI to supplement RT-MRI acquisition was also tested. Results: The RT images with temporal resolutions < 100 ms demonstrated low distortion and image artifacts, and higher reader assessment scores. Static MRI scans showed the ability to assess anatomical structures of interest in the wrist. Conclusion: RT-MRI of the wrist at a high temporal resolution, coupled with static MRI, is feasible with a high-performance 0.55T system, and may enable improved assessment of wrist dynamic dysfunction and instability. Advances in knowledge: Real-time MRI of the moving wrist is feasible with high-performance 0.55T and may improve the evaluation of dynamic dysfunction of the wrist.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparison of image quality and diagnostic efficacy of routine clinical lumbar spine imaging at 0.55T and 1.5/3T;European Journal of Radiology;2024-06

2. Imaging Pitfalls;Medical Radiology;2024

3. MRI Techniques;Medical Radiology;2024

4. New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal;Magnetic Resonance Materials in Physics, Biology and Medicine;2023-10-30