RRIMS: Radiation Risk In Mammography Screening — model evaluation

Author:

Hooshmand Sahand1ORCID,Reed Warren M.1,Suleiman Mo'ayyad E.1,Brennan Patrick C.1

Affiliation:

1. Faculty of Medicine and Health, Discipline of Medical Imaging Sciences, The University of Sydney, SusanWakil Health Building (D18), Sydney, Australia

Abstract

Objective The Radiation Risk In Mammography Screening (RRIMS) model was introduced as a novel tool to help females accurately calculate their lifetime mean glandular dose (MGD) and estimate their population-level risk of radiation-induced breast cancer incidence and mortality. Methods The model’s accuracy was evaluated by comparing the received MGD of 317 women who had undergone a total of 733 visits across one to four rounds of screening. This was achieved by comparing the RRIMS predicted dose values with the same examination dose calculated manually by hand. Qualitative and quantitative statistical analyses were performed to assess the percentage difference (% diff) or agreement between the two values. Results Qualitative statistical analysis using the Bland–Altman plots demonstrated a statistically significant bias for the % diff between the manually calculated and RRIMS predicted dose values, where the mean (bias) was −2.02% with an upper and lower limit of agreement of 40.24% and −44.27%, respectively. Quantitative statistical analysis revealed an intraclass correlation coefficient (ICC, 3,1) of 0.64 (p-value < 0.001) and a Kendall’s W of 0.83 (p-value < 0.001). Conclusion The results indicate a statistically significant and reasonably good level of agreement between the manually calculated vs RRIMS predicted dose values. This work was focused on one of the major mammography equipment manufacturers that is Hologic, however there is potential for a multivendor applicability study of this model with future iterations. This will further improve upon this innovative dose and risk prediction tool that can empower healthcare professionals when making informed decisions and enhance patient care. Advances in knowledge This paper assesses the precision of the dose and risk model that our team has previously established. The results bring us one step closer to providing females and clinicians with a useful tool that can help explain and contextualise the benefits and risks associated with screening mammography.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3