Comparison of 3D T1-SPACE and DSA in evaluation of intracranial in-stent restenosis

Author:

Shao Qiuji1,Li Qiang2,Wu Qiaowei1,Li Tianxiao1ORCID,Li Li1,Chang Kaitao1

Affiliation:

1. Department of Cerebrovascular Disease, Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Henan University People's Hospital, Zhengzhou, China

2. Department of Radiology, Department of Cerebrovascular Disease, Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Henan University People's Hospital, Zhengzhou, China

Abstract

Objective: In-stent restenosis (ISR) after stenting for intracranial stenosis is a significant issue. This study aimed to evaluate the usefulness of the 3D T1-SPACE technique in the follow-up of patients after stent implantation. Methods: Fifteen patients with intracranial arterial stenosis were prospectively enrolled 6–8 months after stenting. Digital subtraction angiography (DSA) and 3D T1-SPACE imaging were performed to evaluate the degree of stenosis and the enhancement of the vessel wall. Bland–Altman plots were used to assess the agreement between the two imaging methods, and the Pearson correlation coefficient was calculated as a measure of the linear correlation. Results: Eight Enterprise stents and seven Wingspan stents were used in 15 patients. The follow-up DSA after 6–8 months showed that the degree of stenosis was 40% (range, 30–72%), and ISR occurred in 4 of 15 (26.7%) lesions. The degree of stenosis assessed using the 3D T1-SPACE imaging technique was 35% (range, 30–75%). All four patients with ISR demonstrated significant enhancement. The Pearson correlation coefficient between the two methods was 0.959 (p < 0.05), and the Bland–Altman plot showed that all data points were within the consistency limits ([Formula: see text] ± 1.96 s). Conclusion: As a non-invasive imaging modality, 3D T1-SPACE showed great consistency with DSA in measuring the degree of stenosis after intracranial stenting. It may be used as an optional method for detecting ISR. Advances in knowledge: This study evaluated the usefulness of 3D T1-SPACE technique in the follow-up of patients after stent implantation, which could be used as an optional and non-invasive method in detection of in-stent restenosis.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3