Signal-to-noise ratio assessment of muscle diffusion tensor imaging using single image set and validation by the difference image method

Author:

Wang Zhiyue J.12,Yamamura Jin3,Keller Sarah34

Affiliation:

1. Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA

2. Department of Radiology, Children’s Health, Dallas, Texas, USA

3. Department of Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

4. Department of Radiology, Charité University Medicine Berlin, Berlin, Germany

Abstract

Objective: Signal-to-noise ratio (SNR) assessment is essential for accurate quantification of diffusion tensor imaging (DTI) metrics and usually requires the use of a difference image method using duplicate images. We aimed to estimate the SNR of DTI of thigh muscles using a single image set without duplicate images. Methods: DTI of one thigh were acquired on a 3 T scanner from 15 healthy adults, and scans with number of signal averages (NSA) = 4 and 8 were repeatedly acquired. SNR were evaluated for six thigh muscles. For SNR calculation from a single image set, diffusion-weighted images with similar diffusion encoding directions were grouped into pairs. The difference image of each pair was high-pass filtered in k-space to yield noise images. Noise images were also calculated with a difference method using two image sets as a reference. Subjects were divided into two groups for filter optimization and validation, respectively. The coefficient of repeatability (CR) of the SNR obtained from the two methods was also evaluated separately. Results: Bland–Altman analysis comparing the single image set method and the reference showed 95% limits of agreement of −9.2 to 9.2% for the optimization group and −12.5 to 12.6% for the validation group. The SNR measurement had a CR of 21.1% using the reference method, and 13.8% using the single image set method. Conclusion: The single image method can be used for DTI SNR assessment and offers better repeatability. Advances in knowledge: SNR of skeletal muscle DTI can be assessed for any data set without duplicate images.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3